Print Email Facebook Twitter EMS wave logger data processing Title EMS wave logger data processing Author Verhagen, H.J. Faculty Civil Engineering and Geosciences Department Hydraulic Engineering Date 2013-03-01 Abstract Waves can be measured in several ways. One way of measuring waves is by measuring the wave pressure at a certain depth using a pressure sensor and calculate the wave information from the pressure record. The EMS wave logger uses a Honeywell MLH 050 PGP 06A pressure sensor. The information is stored by the logger on a SD card. The software in the logger controls the sample durations (from 1 to 30 minutes) and the sample intervals (from 15 min to 3 hours). The sampling rate is fixed to 4 Hz. In this report software is presented to evaluate the data from the wavelogger Subject pressure sensorwave measurementswater level measurementswave sprectrum To reference this document use: http://resolver.tudelft.nl/uuid:7cf8c9e7-d525-48ed-83cb-ef01368e6279 Publisher TU Delft, Department Hydraulic Engineering ISSN 01696548 Source Communications on Hydraulic and Geotechnical Engineering, No. 2013-031 Part of collection Institutional Repository Document type report Rights (c) Henk Jan Verhagen Files PDF Wave_logger_processing.pdf 952.79 KB Close viewer /islandora/object/uuid:7cf8c9e7-d525-48ed-83cb-ef01368e6279/datastream/OBJ/view