Print Email Facebook Twitter Coded Excitation for Doppler Ultrasound Imaging of The Brain Title Coded Excitation for Doppler Ultrasound Imaging of The Brain Author ZHU, LEXI (TU Delft Electrical Engineering, Mathematics and Computer Science) Contributor Leus, G.J.T. (mentor) Kruizinga, Pieter (graduation committee) Degree granting institution Delft University of Technology Corporate name Delft University of Technology Programme Electrical Engineering | Signals and Systems Date 2023-08-25 Abstract Doppler ultrasound imaging of cerebral blood flow faces challenges arising from a low signal-to-noise ratio (SNR) and a wide dynamic range. Echo signals received from blood cells are significantly weaker compared to surrounding tissues, such as the skull or brain soft tissue, resulting in inhibited visualization of small blood vessels and deep brain areas. To address this issue, this thesis explored the feasibility of employing and improving coded excitation techniques to enhance the SNR of Doppler ultrasound images. Furthermore, an optimized code for Doppler ultrasound imaging is designed, represented by a generalized encoding matrix. The research begins with the definition of a linear signal model that incorporates the encoding matrix. Subsequently, a trace-constraint optimization problem is formulated based on maximizing the Fisher information matrix to find the optimized encoding matrix. The feasibility and performance of the optimized encoding matrix are assessed through simulations on both small and large array settings, which operate above Nyquist sampling frequency and under Nyquist sampling frequency respectively. The imaging results indicate that the optimized code exhibits higher SNR in deep image regions compared to existing coded excitation methods like Barker code while using the same number of transmissions, bit length, and same average transmit energy, albeit with a trade-off of decreased axial resolution. Nonetheless, this resolution degradation can be mitigated through the application of the iterative imaging technique LSQR. Finally, the optimized code is tested in a clinical transducer setting, and a blood flow simulation is conducted. The outcomes showcase the capacity of the proposed optimized code to enable higher SNR in Doppler ultrasound imaging and more accurate and informative clinical assessments. Subject Doppler ultrasound imagingCoded excitationOptimization To reference this document use: http://resolver.tudelft.nl/uuid:2308611c-3ff6-46fc-aa50-16efa539b8df Part of collection Student theses Document type master thesis Rights © 2023 LEXI ZHU Files PDF MSc_thesis_Lixiang_Zhu.pdf 19.4 MB Close viewer /islandora/object/uuid:2308611c-3ff6-46fc-aa50-16efa539b8df/datastream/OBJ/view