document
Shabanimotlagh, M. (author), Raghunathan, S.B. (author), Bera, D. (author), Chen, Z. (author), Chen, C. (author), Daeichin, V. (author), Pertijs, M.A.P. (author), Bosch, J.G. (author), de Jong, N. (author), Verweij, M.D. (author)
Echocardiography is a portable, safe, and low-cost imaging technique for accurate assessment of the heart. In transesophageal echocardiography (TEE) the esophagus is utilized as the imaging window to examine the cardiac anatomy and function. In conventional TEE probes, a one-dimensional (1D) ultrasound array is employed to obtain two-dimensional...
abstract 2017
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Typically, ultrasonic flow meters assume linear wave propagation. Nevertheless, if the transducers of an ultrasonic flow sensor excite a pressure wave with a high amplitude, nonlinear wave propagation effects become significant. The appearance of higher harmonics increases the bandwidth of the received signal, which may potentially lead to a...
conference paper 2018
document
Mozaffarzadeh, M. (author), Verweij, M.D. (author), Daeichin, V. (author), de Jong, N. (author), Renaud, G.G.J. (author)
Transcranial ultrasound imaging is a suitable technology for diagnosis of strokes as it is safe, portable, relatively inexpensive and available in emergency medicine services, however it currently offers poor image quality due to the phase aberration caused by the human skull. In this work, we evaluate an approach for two-dimensional...
conference paper 2021
document
Hakakzadeh, Soheil (author), Mozaffarzadeh, M. (author), Mostafavi, Seyed Masood (author), Amjadian, Mohammadreza (author), Kavehvash, Zahra (author), Verweij, M.D. (author), de Jong, N. (author)
In circular photoacoustic computed tomography, for data acquisition, a single-element transducer rotates around the region of interest (ROI). Due to the limited acceptance angle of the finite size transducer, the reconstructed image becomes blurred, and tangential resolution/contrast degrades in off-center locations in the ROI. In this paper, we...
conference paper 2021
document
Fool, F. (author), de Wit, J. (author), Vos, H.J. (author), Bera, D. (author), de Jong, N. (author), Verweij, M.D. (author)
The huge amount of data that needs to be transferred between probe and imaging system becomes a major issue when the data transfer capacity is limited, e.g. in handheld systems, wireless probes and miniaturized probes. The amount of data can be significantly reduced by using two-stage beamforming. The first stage consists of a fixed focus...
conference paper 2018
document
Waasdorp, R. (author), Mugge, W. (author), Vos, H.J. (author), de Groot, J.H. (author), de Jong, N. (author), Verweij, M.D. (author), Schouten, A.C. (author), Daeichin, V. (author)
Current methods to track the progression and evaluate treatment of muscular dystrophies are scarce. The electromechanical delay (EMD), defined as the time lag from muscle electrical activity to motion onset, has been proposed as a biomarker, but provides only limited insight in the pathophysiol-ogy of muscle function. This work proposes and...
conference paper 2019
document
van Willigen, D.M. (author), Mozaffarzadeh, M. (author), Noothout, E.C. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Daeichin, V. (author)
This paper presents the integration steps towards a prototype forward-looking intra-vascular ultrasound probe. An ASIC (Application Specific Integrated Circuit) is laser cut to create a 1.6mm circular shaped die that can be integrated at the tip of a small catheter. The ASIC is designed such that it can be used to transmit and receive on 64...
conference paper 2019
document
Ossenkoppele, B.W. (author), Daeichin, V. (author), Rodriguez Hernandez, K.E. (author), de Jong, N. (author), Verweij, M.D. (author), Schouten, A.C. (author), Mugge, W. (author)
Effective treatment of movement disorders requires thorough understanding of human limb control. Joint dynamics can be assessed using robotic manipulators and system identification. Due to tendon compliance, joint angle and muscle length are not proportional. This study uses plane-wave ultrasound imaging to investigate the dynamic relation...
conference paper 2019
document
Hosseini, Fatemeh (author), Mozaffarzadeh, M. (author), Mahlooiifar, Ali (author), Verweij, M.D. (author), de Jong, N. (author)
In recent years, transcranial photoacoustic (TPA) imaging has become a popular modality for diagnosis of brain disorders. However, due to the presence of skull, TPA images are strongly degraded. Acoustically, this degradation is mainly categorized into the phase aberration, mode-converted shear waves, and multiple scattering. Previous studies...
conference paper 2022
document
Wei, Luxi (author), Wahyulaksana, G. (author), Boni, Enrico (author), Noothout, E.C. (author), Tortoli, Piero (author), van der Steen, A.F.W. (author), de Jong, N. (author), Verweij, M.D. (author), Vos, H.J. (author)
Volumetric echocardiography can potentially give a more complete picture of cardiac dynamics than its two-dimensional (2D) counterpart. Current clinical volumetric imaging probes have relatively low frame rates, and often require ECG gating to stitch together an entire volume. This makes measuring fast dynamics of the heart as well as imaging...
conference paper 2023
document
Luijten, Ben (author), Ossenkoppele, B.W. (author), de Jong, N. (author), Verweij, M.D. (author), Eldar, Yonina C. (author), Mischi, Massimo (author), van Sloun, Ruud J.G. (author)
Ultrasound imaging is an attractive imaging modality due to its low-cost and real-time feedback, although it often falls short in image quality compared to MRI and CT imaging. Conventional ultrasound image reconstruction, such as Delay-and-Sum beamforming, is derived from maximum-likelihood estimation. As such, no prior information is exploited...
conference paper 2023
document
Ossenkoppele, B.W. (author), Wei, Luxi (author), Luijten, Ben (author), Vos, H.J. (author), de Jong, N. (author), Van Sloun, Ruud J.G. (author), Verweij, M.D. (author)
3-D contrast enhanced ultrasound enables better visualization of inherently 3-D vascular geometries compared to an intersecting plane. Additionally, it would allow the application of motion correction techniques for all directions. Both contrast detection and motion correction work better on high-frame rate data. However high-frame rate 3-D...
conference paper 2022
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, J. G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This paper presents a pitch-matched transceiver ASIC integrated with a 2-D transducer array for a wearable ultrasound device for transfontanelle ultrasonography. The ASIC combines 8-fold multiplexing, 4-channel micro-beamforming (μ BF) and sub-array-level digitization to achieve a 128-fold channel-count reduction. The μ BF is based on passive...
conference paper 2023
document
Massaad Mouawad, J.M. (author), van Willigen, D.M. (author), van Neer, P.L.M.J. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Current ultrasonic clamp-on flow meters are based on single-element transducers that require manual calibration by aligning these to a fixed acoustic path. Moreover, the size and operational frequency of the transducers cannot be adapted to the parameters of the pipe and the liquid, which are in practice not precisely known a priory. A set of...
conference paper 2019
document
Fool, F. (author), Vos, H.J. (author), Shabanimotlagh, M. (author), Soozande, M. (author), Mozaffarzadeh, M. (author), Kim, T. (author), Kang, E. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
To accurately investigate the state of the carotid artery by the local haemodynamics and motion of the plaque using ultrasound, high-frame rate volumetric imaging is necessary. We have specifically designed a matrix array for this purpose. In this proceeding we will focus on imaging a volumetric flow profile using this matrix. For this...
conference paper 2019
document
Guo, P. (author), Fool, F. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
The integration of 2D ultrasonic transducer arrays and pitch-matched ASICs has enabled the realization of various 3D ultrasound imaging devices in recent years [1]-[3]. As applications such as 3D intravascular ultrasonography, intra-cardiac echocardiography, and trans-fontanelle ultrasonography call for miniaturization and improved spatial...
conference paper 2022
document
Colas, Quorentin (author), Bantignies, Claire (author), Perroteau, Marie (author), Porcher, Nicolas (author), Vassal, Steeven (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
Three-dimensional ultrasound has initially been used to address volumetric imaging for diagnostic purposes and represents the leading-edge technological orientation in both transducer and IC (integrated circuit) architecture and design. However, new applications are coming up like biomarker measurements, preoperative navigation, real time...
conference paper 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Kim, Taehoon (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Over the past decades, real-time three-dimensional (3D) medical ultrasound has attracted much attention since it enables clinicians to diagnose more accurately. This calls for ultrasound matrix transducers with a large number of elements, which can be interfaced with an application-specific integrated circuit (ASIC) for data reduction. An...
conference paper 2021
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Soozande, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, C. (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
Intra-cardiac echography (ICE) probes (Fig. 32.2.1) are widely used in electrophysiology for their good procedure guidance and relatively safe application. ASICs are increasingly employed in these miniature probes to enhance signal quality and reduce the number of connections needed in mm-diameter catheters [1]-[5]. 3D visualization in real...
conference paper 2022
document
Leinders, S.M. (author), Westerveld, W.J. (author), Pozo, J. (author), Neer, P.L.M.J. (author), Snyder, B. (author), O'Brien, P. (author), Urbach, H.P. (author), de Jong, N. (author), Verweij, M.D. (author)
With the increasing use of ultrasonography, especially in medical imaging, novel fabrication techniques together with novel sensor designs are needed to meet the requirements for future applications like three-dimensional intercardiac and intravascular imaging. These applications require arrays of many small elements to selectively record the...
journal article 2015
Searched for: +
(1 - 20 of 78)

Pages