Searched for: +
(1 - 10 of 10)
document
Pasma, J.H. (author), Assländer, Lorenz (author), van Kordelaar, J. (author), de Kam, Digna (author), Mergner, Thomas (author), Schouten, A.C. (author)
The Independent Channel (IC) model is a commonly used linear balance control model in the frequency domain to analyze human balance control using system identification and parameter estimation. The IC model is a rudimentary and noise-free description of balance behavior in the frequency domain, where a stable model representation is not...
journal article 2018
document
Filatova, O.G. (author), van Vliet, L.J. (author), Schouten, A.C. (author), Kwakkel, Gert (author), van der Helm, F.C.T. (author), Vos, F.M. (author)
Better insight into white matter (WM) alterations after stroke onset could help to understand the underlying recovery mechanisms and improve future interventions. MR diffusion imaging enables to assess such changes. Our goal was to investigate the relation of WM diffusion characteristics derived from diffusion models of increasing complexity...
journal article 2018
document
Fu, X. (author), Rol, M.A. (author), Bultink, C.C. (author), van Someren, J. (author), Khammassi, N. (author), Ashraf, I. (author), Vermeulen, R.F.L. (author), de Sterke, J.C. (author), Vlothuizen, W.J. (author), Schouten, R.N. (author), Almudever, Carmen G. (author), DiCarlo, L. (author), Bertels, K.L.M. (author)
Quantum computers promise to solve certain problems that are intractable for classical computers, such as factoring large numbers and simulating quantum systems. To date, research in quantum computer engineering has focused primarily at opposite ends of the required system stack: devising high-level programming languages and compilers to...
conference paper 2017
document
Yang, Y. (author), Guliyev, Bekir (author), Schouten, A.C. (author)
Mechanical perturbations applied to the wrist joint typically evoke a stereotypical sequence of cortical and muscle responses. The early cortical responses (<100 ms) are thought be involved in the “rapid” transcortical reaction to the perturbation while the late cortical responses (>100 ms) are related to the “slow” transcortical reaction....
journal article 2017
document
Pasma, J.H. (author), Boonstra, T.A. (author), van Kordelaar, J. (author), Spyropoulou, V. (author), Schouten, A.C. (author)
Balance control models are used to describe balance behavior in health and disease. We identified the unique contribution and relative importance of each parameter of a commonly used balance control model, the Independent Channel (IC) model, to identify which parameters are crucial to describe balance behavior. The balance behavior was expressed...
journal article 2017
document
Pasma, J.H. (author), van Kordelaar, J. (author), de Kam, D. (author), Weerdesteyn, V. (author), Schouten, A.C. (author), van der Kooij, H. (author)
Background: Closed loop system identification (CLSIT) is a method to disentangle the contribution of underlying systems in standing balance. We investigated whether taking into account lower leg muscle activation in CLSIT could improve the reliability and accuracy of estimated parameters identifying the underlying systems. Methods: Standing...
journal article 2017
document
Pasma, J.H. (author), Engelhart, D. (author), Maier, A.B. (author), Aarts, R.G.K.M. (author), Van Gerven, J.M.A. (author), Arendzen, J.H. (author), Schouten, A.C. (author), Meskers, C.G.M. (author), Van der Kooij, H. (author)
Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques. Methods In twelve healthy...
journal article 2016
document
Yang, Y. (author), Solis Escalante, T. (author), van de Ruit, M.L. (author), van der Helm, F.C.T. (author), Schouten, A.C. (author)
Coupling between cortical oscillations and muscle activity facilitates neuronal communication during motor control. The linear part of this coupling, known as corticomuscular coherence, has received substantial attention, even though neuronal communication underlying motor control has been demonstrated to be highly nonlinear. A full assessment...
journal article 2016
document
Lobo-Prat, J. (author), Keemink, A.Q.L. (author), Stienen, A.H.A. (author), Schouten, A.C. (author), Veltink, P.H. (author), Koopman, B.F.J.M. (author)
Background: The performance capabilities and limitations of control interfaces for the operation of active movement-assistive devices remain unclear. Selecting an optimal interface for an application requires a thorough understanding of the performance of multiple control interfaces. Methods: In this study the performance of EMG-, force- and...
journal article 2014
document
Mugge, W. (author), Van der Helm, F.C.T. (author), Schouten, A.C. (author)
Complex regional pain syndrome (CRPS) is characterized by pain and disturbed blood flow, temperature regulation and motor control. Approximately 25% of cases develop fixed dystonia. The origin of this movement disorder is poorly understood, although recent insights suggest involvement of disturbed force feedback. Assessment of sensorimotor...
journal article 2013
Searched for: +
(1 - 10 of 10)