Searched for: +
(1 - 18 of 18)
document
Chmarra, M.K. (author), Kolkman, W. (author), Jansen, F.W. (author), Grimbergen, C.A. (author), Dankelman, J. (author)
journal article 2007
document
Chmarra, M.K. (author), Jansen, F.W. (author), Grimbergen, C.A. (author), Dankelman, J. (author)
Aims- Minimally invasive surgery (MIS) requires a high degree of eye–hand coordination from the surgeon. To facilitate the learning process, objective assessment systems based on analysis of the instruments’ motion are being developed. To investigate the influence of performance on motion characteristics, we examined goaloriented movements in a...
journal article 2007
document
Chmarra, M.K. (author), Dankelman, J. (author), Van den Dobbelsteen, J.J. (author), Jansen, F.W. (author)
Background - Not much is known about the exact role offorce feedback in laparoscopy. This study aimed to determine whether force feedback influences movements of instruments during training in laparoscopic tasks and whether force feedback is required for training in basic laparoscopic force application tasks. Methods - A group of 19 gynecologic...
journal article 2008
document
Chmarra, M.K. (author), Klein, S. (author), De Winter, J.C.F. (author), Jansen, F.W. (author), Dankelman, J. (author)
Background - From the clinical point of view, it is important to recognize residents’ level of expertise with regard to basic psychomotor skills. For that reason, surgeons and surgical organizations (e.g., Acreditation Council for Graduate Medical Education, ACGME) are calling for assessment tools that credential residents as technically...
journal article 2009
document
Horeman, T. (author), Jansen, F.W. (author), Dankelman, J. (author)
Background - The risk of obtaining a postsurgical infection depends highly on the air quality surrounding the exposed tissue, surgical instruments, and materials. Many isolators for open surgery have been invented to create a contained sterile volume around the exposed tissue. With the use of an isolator, a surgical procedure can be performed...
journal article 2010
document
Horeman, T. (author), Rodrigues, S.P. (author), Jansen, F.W. (author), Dankelman, J. (author), Van den Dobbelsteen, J.J. (author)
Background - To improve endoscopic surgical skills, an increasing number of surgical residents practice on box or virtual-reality (VR) trainers. Current training is mainly focused on hand–eye coordination. Training methods that focus on applying the right amount of force are not yet available. Methods - The aim of this project is to develop a...
journal article 2010
document
Horeman, T. (author), Rodrigues, S.P. (author), Van den Dobbelsteen, J.J. (author), Jansen, F.W. (author), Dankelman, J. (author)
Background - To improve endoscopic surgical skills, an increasing number of surgical residents practice on box or virtual reality (VR) trainers. Current training is focused mainly on hand–eye coordination. Training methods that focus on applying the right amount of force are not yet available. Methods - The aim of this project is to develop a...
journal article 2011
document
Rodrigues, S.P. (author), Horeman, T. (author), Dankelman, J. (author), Van den Dobbelsteen, J.J. (author), Jansen, F.W. (author)
It is generally assumed that safety of tissue manipulations during (laparoscopic) surgery is related to the magnitude of force that is exerted on the tissue. To provide trainees with performance feedback about tissuehandling skills, it is essential to define objective criteria for judging the safety of applied forces. To be of clinical relevance...
journal article 2011
document
Henken, K.R. (author), Jansen, F.W. (author), Klein, J. (author), Stassen, L.P.S. (author), Dankelman, J. (author), Van den Dobbelsteen, J.J. (author)
Background Technological developments allow for a variety of applications of video recording in health care, including endoscopic procedures. Although the value of video registration is recognized, medicolegal concerns regarding the privacy of patients and professionals are growing. A clear understanding of the legal framework is lacking....
journal article 2012
document
Okken, L.M. (author), Chmarra, M.K. (author), Hiemstra, E. (author), Jansen, F.W. (author), Dankelman, J. (author)
Various steerable instruments with flexible distal tip have been developed for laparoscopic surgery. The problem of steering such instruments, however, remains a challenge, because no study investigated which control method is the most suitable. This study was designed to examine whether thumb (joystick) or wrist control method is designated for...
journal article 2012
document
Rodrigues, S.P. (author), Ter Kuile, M. (author), Dankelman, J. (author), Jansen, F.W. (author)
This study was conducted to adapt and validate a patient safety (PS) framework for minimally invasive surgery (MIS) as a first step in understanding the clinical relevance of various PS risk factors in MIS. Eight patient safety risk factor domains were identified using frameworks from a systems approach to patient safety. A questionnaire was...
journal article 2012
document
Horeman, T. (author), Dankelman, J. (author), Jansen, F.W. (author), Van den Dobbelsteen, J.J. (author)
Box trainers equipped with sensors may help in acquiring objective information about a trainee's performance while performing training tasks with real instruments. The main aim of this study is to investigate the added value of force parameters with respect to commonly used motion and time parameters such as path length, motion volume, and task...
journal article 2013
document
Blikkendaal, Mathijs D. (author), Driessen, Sara R C (author), Rodrigues, Sharon P. (author), Rhemrev, Johann P T (author), Smeets, Maddy J G H (author), Dankelman, J. (author), van den Dobbelsteen, J.J. (author), Jansen, F.W. (author)
Background: Minimally invasive surgery (MIS) is frequently compromised by surgical flow disturbances due to technology- and equipment-related failures. Compared with MIS in a conventional cart-based OR, performing MIS in a dedicated integrated operating room (OR) is supposed to be beneficial to patient safety. The aim of this study was to...
journal article 2017
document
Blikkendaal, Mathijs D. (author), Driessen, Sara R C (author), Rodrigues, Sharon P. (author), Rhemrev, J.P.T. (author), Smeets, M.J.G.H. (author), Dankelman, J. (author), van den Dobbelsteen, J.J. (author), Jansen, F.W. (author)
Background: During the implementation of new interventions (i.e., surgical devices and technologies) in the operating room, surgical safety might be compromised. Current safety measures are insufficient in detecting safety hazards during this process. The aim of the study was to observe whether surgical teams are capable of measuring surgical...
journal article 2018
document
Overtoom, Evelien M. (author), Horeman, T. (author), Jansen, F.W. (author), Dankelman, J. (author), Schreuder, Henk W.R. (author)
OBJECTIVES: To provide a systematic overview of the literature assessing the value of haptic and force feedback in current simulators teaching laparoscopic surgical skills. DATA SOURCES: The databases of Pubmed, Cochrane, Embase, Web of Science, and Google Scholar were searched to retrieve relevant studies published until January 31st, 2017....
review 2019
document
Rodríguez, M. (author), Camba-Lamas, D. (author), Oropesa, I. (author), Juhos, K. (author), Wauben, L.S.G.L. (author), Dankelman, J. (author), Jansen, F. W. (author), Weber, G. (author), Gómez, E. J. (author), Sánchez-González, P. (author)
MIS-SIM is a virtual reality (VR) environment designed and developed for the creation of virtual scenarios that can be used to train and acquire basic and advance laparoscopic skills. The environment is composed by a task editor where a content creator design and develop tasks for the simulator to play. Once they are completed, objective...
conference paper 2020
document
de Ridder, Else F. (author), Friedericy, Herman J. (author), van der Eijk, A.C. (author), Dankelman, J. (author), Jansen, F.W. (author)
Highlights: What are the main findings? Using the HSMEA, it is possible to systematically reduce operating room waste. The HSMEA identifies carbon hotspots of surgical waste based on waste stream analysis. Solutions for improvement are found by applying the six Rs of waste management. What is the implication of the main finding? A...
journal article 2022
document
Postema, R.R. (author), Hardon, S.F. (author), Cefai, David (author), Dankelman, J. (author), Jansen, F.W. (author), Camenzuli, Christian (author), Calleja-Agius, Jean (author), Horeman, T. (author)
Background: <br/>Veress needles (VN) are commonly used in establishing pneumoperitoneum in laparoscopic surgery. Previously, a VN with a new safety mechanism ‘VeressPLUS’ needle (VN+) was developed to reduce the amount of overshoot.<br/><br/>Methods: <br/>Eighteen participants (novices, intermediates, and experts) performed in total of 248...
journal article 2023
Searched for: +