Searched for: +
(1 - 20 of 40)

Pages

document
Shabanimotlagh, M. (author), Raghunathan, S.B. (author), Bera, D. (author), Chen, Z. (author), Chen, C. (author), Daeichin, V. (author), Pertijs, M.A.P. (author), Bosch, J.G. (author), de Jong, N. (author), Verweij, M.D. (author)
Echocardiography is a portable, safe, and low-cost imaging technique for accurate assessment of the heart. In transesophageal echocardiography (TEE) the esophagus is utilized as the imaging window to examine the cardiac anatomy and function. In conventional TEE probes, a one-dimensional (1D) ultrasound array is employed to obtain two-dimensional...
abstract 2017
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, J. G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This paper presents a pitch-matched transceiver ASIC integrated with a 2-D transducer array for a wearable ultrasound device for transfontanelle ultrasonography. The ASIC combines 8-fold multiplexing, 4-channel micro-beamforming (μ BF) and sub-array-level digitization to achieve a 128-fold channel-count reduction. The μ BF is based on passive...
conference paper 2023
document
Simoes dos Santos, D. (author), Fool, F. (author), Kim, Taehoon (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Over the past decades, real-time three-dimensional (3D) medical ultrasound has attracted much attention since it enables clinicians to diagnose more accurately. This calls for ultrasound matrix transducers with a large number of elements, which can be interfaced with an application-specific integrated circuit (ASIC) for data reduction. An...
conference paper 2021
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Typically, ultrasonic flow meters assume linear wave propagation. Nevertheless, if the transducers of an ultrasonic flow sensor excite a pressure wave with a high amplitude, nonlinear wave propagation effects become significant. The appearance of higher harmonics increases the bandwidth of the received signal, which may potentially lead to a...
conference paper 2018
document
Colas, Quorentin (author), Bantignies, Claire (author), Perroteau, Marie (author), Porcher, Nicolas (author), Vassal, Steeven (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
Three-dimensional ultrasound has initially been used to address volumetric imaging for diagnostic purposes and represents the leading-edge technological orientation in both transducer and IC (integrated circuit) architecture and design. However, new applications are coming up like biomarker measurements, preoperative navigation, real time...
conference paper 2022
document
van Willigen, D.M. (author), Mozaffarzadeh, M. (author), Noothout, E.C. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Daeichin, V. (author)
This paper presents the integration steps towards a prototype forward-looking intra-vascular ultrasound probe. An ASIC (Application Specific Integrated Circuit) is laser cut to create a 1.6mm circular shaped die that can be integrated at the tip of a small catheter. The ASIC is designed such that it can be used to transmit and receive on 64...
conference paper 2019
document
Massaad Mouawad, J.M. (author), van Willigen, D.M. (author), van Neer, P.L.M.J. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Current ultrasonic clamp-on flow meters are based on single-element transducers that require manual calibration by aligning these to a fixed acoustic path. Moreover, the size and operational frequency of the transducers cannot be adapted to the parameters of the pipe and the liquid, which are in practice not precisely known a priory. A set of...
conference paper 2019
document
Fool, F. (author), Vos, H.J. (author), Shabanimotlagh, M. (author), Soozande, M. (author), Mozaffarzadeh, M. (author), Kim, T. (author), Kang, E. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
To accurately investigate the state of the carotid artery by the local haemodynamics and motion of the plaque using ultrasound, high-frame rate volumetric imaging is necessary. We have specifically designed a matrix array for this purpose. In this proceeding we will focus on imaging a volumetric flow profile using this matrix. For this...
conference paper 2019
document
Guo, P. (author), Fool, F. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
The integration of 2D ultrasonic transducer arrays and pitch-matched ASICs has enabled the realization of various 3D ultrasound imaging devices in recent years [1]-[3]. As applications such as 3D intravascular ultrasonography, intra-cardiac echocardiography, and trans-fontanelle ultrasonography call for miniaturization and improved spatial...
conference paper 2022
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Soozande, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, C. (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
Intra-cardiac echography (ICE) probes (Fig. 32.2.1) are widely used in electrophysiology for their good procedure guidance and relatively safe application. ASICs are increasingly employed in these miniature probes to enhance signal quality and reduce the number of connections needed in mm-diameter catheters [1]-[5]. 3D visualization in real...
conference paper 2022
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Sabbadini, A. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Current ultrasonic clamp-on flow meters consist of a pair of single-element transducers that are carefully positioned before use. This positioning process consists of manually finding the distance between the transducer elements, along the pipe axis, for which maximum signal-to-noise ratio (SNR) is achieved. This distance depends on the sound...
journal article 2021
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe...
journal article 2022
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Acoustic wave propagation in ultrasonic flow measurements is typically assumed to be linear and reciprocal. However, if the transmitting transducer generates a sufficiently high pressure, nonlinear wave propagation effects become significant. In flow measurements, this would translate into more information to estimate the flow and therefore a...
journal article 2021
document
Hopf, Y.M. (author), Ossenkoppele, Boudewine W. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The...
journal article 2022
document
Kim, Taehoon (author), Fool, F. (author), Simoes dos Santos, D. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a...
journal article 2021
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This article presents a compact analog front-end (AFE) circuit for ultrasound receivers with linear-in-dB continuous gain control for time-gain compensation (TGC). The AFE consists of two variable-gain stages, both of which employ a novel complementary current-steering network (CCSN) as the interpolator to realize continuously variable gain....
journal article 2022
document
Simoes dos Santos, D. (author), Ossenkoppele, B.W. (author), Hopf, Y.M. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Objective: Described here is the development of an ultrasound matrix transducer prototype for high-frame-rate 3-D intra-cardiac echocardiography. Methods: The matrix array consists of 16 × 18 lead zirconate titanate elements with a pitch of 160 µm × 160 µm built on top of an application-specific integrated circuit that generates transmission...
journal article 2024
document
van Willigen, D.M. (author), Kang, E. (author), Janjic, Jovana (author), Noothout, E.C. (author), Chang, Z.Y. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This article presents an application-specific integrated circuit (ASIC) designed for intra-vascular ultrasound imaging that interfaces 64 piezoelectric transducer elements to an imaging system using a single micro-coaxial cable. Thus, it allows a single-element transducer to be replaced by a transducer array to enable 3-D imaging. The 1.5-mm...
journal article 2021
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), Willigen, D. M. van (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
During ultrasonic clamp-on flow metering, Lamb waves propagating in the pipe wall may limit the measurement accuracy by introducing absolute errors in the flow estimates. Upon reception, these waves can interfere with the up and downstream waves refracting from the liquid, and disturb the measurement of the transit time difference that is used...
journal article 2020
document
Hopf, Y.M. (author), Ossenkoppele, B.W. (author), Soozande, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this letter, a compact high-voltage (HV) transmit circuit for dense 2-D transducer arrays used in 3-D ultrasonic imaging systems is presented. Stringent area requirements are addressed by a unipolar pulser with embedded transmit/receive switch. Combined with a capacitive HV level shifter, it forms the ultrasonic HV...
journal article 2022
Searched for: +
(1 - 20 of 40)

Pages