Searched for: +
(1 - 8 of 8)
document
Vertongen, J. (author), Kamper, Derek G. (author), Smit, G. (author), Vallery, H. (author)
The large interest in robot hands and active hand prostheses has in recent years been joined by that in active hand orthoses. Despite the differences in intended uses, these three categories of artificial hand devices share key characteristics. Examination of the commonalities could stimulate future design. Thus, in this article, we undertook...
journal article 2020
document
Haverkate, L. (author), Smit, G. (author), Plettenburg, D.H. (author)
Study Design: Experimental trial. Background: The functional performance of currently available body-powered prostheses is unknown. Objective: The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices. Methods: Twenty-one able-bodied subjects (n=21, age...
journal article 2014
document
Smit, G. (author), Plettenburg, D.H. (author), Van der Helm, F.C.T. (author)
Rejection rates of upper limb prostheses are high (23-45%). Amputees indicate that the highest design priority should be reduction of the mass of the prosthetic device. Despite all efforts, the mass of the new prosthetic hands is 35-73% higher than that of older hands. Furthermore current hands are thicker than a human hand, they operate slower...
journal article 2014
document
Smit, G. (author), Plettenbrug, D.H. (author), Van der Helm, F.C.T. (author)
Background: Cosmetic gloves that cover a prosthetic hand have a parasitic positive stiffness that counteracts the flexion of a finger joint. Objectives: Reducing the required input torque to move a finger of a prosthetic hand by compensating the parasitic stiffness of the cosmetic glove. Study design: Experimental, test bench. Methods: The...
journal article 2014
document
Smit, G. (author), Plettenburg, D.H. (author), Van der Helm, F.C. (author)
The goal of this study was to find an efficient method of energy transmission for application in an anthropomorphic underactuated body-powered (BP) prosthetic hand. A pulley-cable finger and a hydraulic cylinder finger were designed and tested to compare the pulley-cable transmission principle with the hydraulic cylinder transmission principle....
journal article 2014
document
Smit, G. (author)
Replacement of a missing hand by an artificial alternative remains one of the biggest challenges in rehabilitation. Although many different terminal devices are available, around 27% of the amputees does not actively use their device and 20% totally refrains from wearing it. There are various reasons for prosthesis abandonment, e.g. wearing...
doctoral thesis 2013
document
Smit, G. (author), Bongers, R.M. (author), Van der Sluis, C.K. (author), Plettenburg, D.H. (author)
Quantitative data on the mechanical performance of upper-limb prostheses are very important in prostheses development and selection. The primary goal of this study was to objectively evaluate the mechanical performance of adult-size voluntary opening (VO) prosthetic terminal devices and select the best tested device. A second goal was to see...
journal article 2012
document
Smit, G. (author), Plettenburg, D.H. (author)
The Delft Institute of Prosthetics and Orthotics has started a research program to develop an improved voluntary closing, body-powered hand prosthesis. Five commercially available voluntary closing terminal devices were mechanically tested: three hands [Hosmer APRL VC hand, Hosmer Soft VC Male hand, Otto Bock 8K24] and two hooks [Hosmer APRL VC...
journal article 2010
Searched for: +
(1 - 8 of 8)