Van de Kuilen, J.W.G. (author)
Timber joints that have been preloaded for 2 to 8 years have been short term tested in accordance with EN 26891. The applied load levels varied between 30% and 50% of the average short term strength. The study comprised nailed, toothed-plate and split-ring joints. All joints were made of spruce and loaded in tension. The test results indicated...