Searched for:
(1 - 8 of 8)
document
Qu, L. (author), Chen, Y. (author), Rooij, R.M. (author), de Jong, P. (author)
This article will contribute to filling the knowledge gap about learning from group methods in (urban and regional) design education, with action research results based on real teaching activities in TU Delft, Faculty of Architecture and the Built Environment (A&BE), conducted and coordinated by the authors. Constructive alignment of the...
journal article 2019
document
Janjic, Jovana (author), Tan, M. (author), Daeichin, V. (author), Noothout, E.C. (author), Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Beurskens, Robert H.S.H. (author), van Soest, G. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author), de Jong, N. (author)
Intravascular ultrasound is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking intravascular ultrasound (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2D array...
journal article 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Noothout, E.C. (author), Chang, Z.Y. (author), Tan, M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a front-end application-specified integrated circuit (ASIC) integrated with a 2-D PZT matrix transducer that enables in-probe digitization with acceptable power dissipation for the next-generation endoscopic and catheter-based 3-D ultrasound imaging systems. To achieve power-efficient massively parallel analog-to-digital...
journal article 2018
document
Daeichin, V. (author), Bera, D. (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Chen, Z. (author), Chen, C. (author), Noothout, E.C. (author), Vos, H.J. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author), More Authors (author)
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a...
journal article 2018
document
Tan, M. (author), Chen, C. (author), Chen, Z. (author), Janjic, Jovana (author), Daeichin, V. (author), Chang, Z.Y. (author), Noothout, E.C. (author), van Soest, G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an area- and power-efficient application-specified integrated circuit (ASIC) for 3-D forward-looking intravascular ultrasound imaging. The ASIC is intended to be mounted at the tip of a catheter, and has a circular active area with a diameter of 1.5 mm on the top of which a 2-D array of piezoelectric transducer elements is...
journal article 2018
document
Bera, D. (author), Raghunathan, S.B. (author), Chen, C. (author), Chen, Z. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Bosch, J.G. (author)
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issues, we have recently...
journal article 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Ponte, Jacco (author), Prins, Christian (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm<sup>2</sup> ASIC, implemented...
journal article 2017
document
Kooiman, Klazina (author), van Rooij, Tom (author), Qin, Bin (author), Mastik, Frits (author), Vos, H.J. (author), Versluis, Michel (author), Klibanov, Alexander L. (author), de Jong, N. (author), Villanueva, Flordeliza S. (author), Chen, Xucai (author)
Acoustic behavior of lipid-coated microbubbles has been widely studied, which has led to several numerical microbubble dynamics models that incorporate lipid coating behavior, such as buckling and rupture. In this study we investigated the relationship between micro-bubble acoustic and lipid coating behavior on a nanosecond scale by using...
journal article 2017