Searched for: author%3A%22Cui%2C+M.%22
(1 - 11 of 11)
document
Bhattacharya, N. (author), Cui, M. (author), Zeitouny, M. (author), Urbach, Paul (author), van den Berg, S. (author)
conference paper 2018
document
Cui, M. (author), Hovenier, J.N. (author), Ren, Y. (author), Vercruyssen, N. (author), Gao, J.R. (author), Kao, T.Y. (author), Hu, Q. (author), Reno, J.L. (author)
We report on both measurements and simulations of the beam profile and wavefront of a single-mode, 3.5?THz quantum cascade wire laser, incorporating a lateral corrugated metal-metal waveguide, 3rd-order distributed feedback grating. The intrinsic wavefront was measured by using a Hartmann wavefront sensor (HWS) without any optical components...
journal article 2013
document
Ren, Y. (author), Hayton, D.J. (author), Hovenier, J.N. (author), Cui, M. (author), Gao, J.R. (author), Klapwijk, T.M. (author), Shi, S.C. (author), Kao, T.Y. (author), Hu, Q. (author), Reno, J.L. (author)
We demonstrate an experimental scheme to simultaneously stabilize the frequency and amplitude of a 3.5 THz third-order distributed feedback quantum cascade laser as a local oscillator. The frequency stabilization has been realized using a methanol absorption line, a power detector, and a proportional-integral-derivative (PID) loop. The amplitude...
journal article 2012
document
Cui, M. (author), Hovenier, J.N. (author), Ren, Y. (author), Polo, A. (author), Gao, J.R. (author)
We demonstrate for the first time that the Hartmann wavefront sensor (HWS) principle can be applied for characterizing the wavefronts of terahertz (THz) electromagnetic radiation. The THz Hartmann wavefront sensor consists of a metallic plate with an array of holes and a twodimensional scanable pyro-electric detector. The THz radiation with...
journal article 2012
document
Ren, Y. (author), Hovenier, J.N. (author), Cui, M. (author), Hayton, D.J. (author), Gao, J.R. (author), Klapwijk, T.M. (author), Shi, S.C. (author), Kao, T.Y. (author), Hu, Q. (author), Reno, J.L. (author)
We report frequency locking of two 3.5-THz third-order distributed feedback (DFB) quantum cascade lasers (QCLs) by using methanol molecular absorption lines, a proportional-integral-derivative controller, and a NbN bolometer. We show that the free-running linewidths of the QCLs are dependent on the electrical and temperature tuning coefficients....
journal article 2012
document
Cui, M. (author), Zeitouny, M.G. (author), Bhattacharya, N. (author), Van den Berg, S.A. (author), Urbach, H.P. (author)
We experimentally demonstrate long distance measurements with a femtosecond frequency comb laser using dispersive interferometry. The distance is derived from the unwrapped spectral phase of the dispersed interferometer output and the repetition frequency of the laser. For an interferometer length of 50 m this approach has been compared to an...
journal article 2011
document
Zeitouny, M.G. (author), Cui, M. (author), Janssen, A.J. (author), Bhattacharya, N. (author), Van den Berg, S.A. (author), Urbach, H.P. (author)
We investigate general properties of the interferograms from a frequency comb laser in a non-linear dispersive medium. The focus is on interferograms at large delay distances and in particular on their broadening, the fringe formation and shape. It is observed that at large delay distances the interferograms spread linearly and that its shape is...
journal article 2011
document
Cui, M. (author)
This thesis is about interferometric distance measurement using ultrashort pulses, with linear measurement techniques in a dispersive medium. Several fields of expertise are combined here: ultrashort pulse propagation in dispersive media, distance measurement interefometry and linear measurement techniques. All our measurements can be mainly...
doctoral thesis 2010
document
Zeitouny, M.G. (author), Cui, M. (author), Bhattacharya, N. (author), Urbach, H.P. (author), Van den Berg, S.A. (author), Janssen, A.J.E.M. (author)
We have investigated correlation patterns generated by a frequency-comb laser in a dispersive unbalanced Michelson interferometer and apply the developed formalism to the case of distance metrology. Due to group velocity dispersion, the position of the brightest fringe of the correlation pattern, which is used for distance determination, cannot...
journal article 2010
document
Cui, M. (author), Zeitouny, M.G. (author), Bhattacharya, N. (author), Van den Berg, S.A. (author), Urbach, H.P. (author), Braat, J.J.M. (author)
We experimentally demonstrate that a femtosecond frequency comb laser can be applied as a tool for longdistance measurement in air. Our method is based on the measurement of cross correlation between individual pulses in a Michelson interferometer. From the position of the correlation functions, distances of up to 50 m have been measured. We...
journal article 2009
document
Cui, M. (author), Bhattacharya, N. (author), Urbach, H.P. (author), Van den berg, S.A. (author)
We experimentally demonstrate that a stabilized femtosecond frequency comb can be applied as a tool for distance measurement. The scheme is based on optical interference between individual pulses in a Michelson type interferometer. The cross-correlation functions between individual pulses with a distance of around 15 meter and 30 meter are...
conference paper 2008
Searched for: author%3A%22Cui%2C+M.%22
(1 - 11 of 11)