- document
-
Mier Escurra, C. (author), Mor, A. R. (author), Vaessen, P.T.M. (author), Lathouwers, A.G.A. (author)One of the main difficulties in measuring partial discharges (PD) in gas-insulated substations (GIS) is the overlapping of pulses at the sensor's location, which distorts the pulse resolution and the charge estimation. This research presents a new method called “synergy,” which identifies and suppresses reflections using magnetic and electric...journal article 2023
- document
-
Vera, Carlos (author), Garnacho, Fernando (author), Klüss, Joni (author), Mier Escurra, C. (author), Álvarez, Fernando (author), Lahti, Kari (author), Khamlichi, Abderrahim (author), Elg, Alf Peter (author), Mor, A. R. (author)The insulation condition of HVDC grids consisting of cable systems, GIS, and converters should be monitored by partial discharge (PD) analysers using artificial intelligence (AI) tools for efficient insulation diagnosis. Although there are many experiences of PD monitoring solutions developed for the supervision of the insulation condition of...journal article 2023
- document
-
Garnacho, Fernando (author), Álvarez, Fernando (author), Elg, Alf Peter (author), Mier Escurra, C. (author), Lahti, Kari (author), Khamlichi, Abderrahim (author), Arcones, Eduardo (author), Klüss, Joni (author), Mor, A. R. (author)On-site partial discharge (PD) measurements have turned out to be a very efficient technique for determining the insulation condition in high-voltage electrical grids (AIS, cable systems, GIS, HVDC converters, etc.); however, there is not any standardised procedure for determining the performances of PD measuring systems. In on-line and on...journal article 2023
- document
-
Mier Escurra, C. (author), Mor, A. R. (author), Vaessen, P.T.M. (author)Partial discharge (PD) measurements in gasinsulated substations (GIS) are tested according to the standard IEC 60270. This “conventional” PD test method applies to electrically small devices. The equipment size increases the resonance, and attenuation, contributing to the total uncertainty. Additionally, when an ultra-high frequency (UHF) sensor...conference paper 2023
- document
-
Mier Escurra, C. (author), Mor, A. R. (author), Castro Heredia, L.C. (author), Vaessen, P.T.M. (author)There are no accepted procedures that quantify the apparent charge of partial discharge (PD) in gas-insulated substations (GIS). This paper proposes a calibration method for PD charge estimation using unconventional electromagnetic sensors: a magnetic loop antenna (inductive coupler) and an electric antenna (capacitive coupler.) The...journal article 2022
- document
-
Mier Escurra, C. (author), Mor, A. R. (author)Recent research has found that Magnetic loop antennas can detect partial discharges (PD) in gas-insulated substations (GIS); however, unbalanced shielded loop (UBSL) antennas are affected by electric field coupling. This research proposes a balanced shielded loop (BSL) adapted for GIS PD sensing with different designs. The frequency response and...conference paper 2022
- document
-
Mier Escurra, C. (author), Mor, A. R. (author)Partial discharges (PD) measurements provide an estimation of the severity of the insulation degradation; additionally, it is used as a unit of standardization. Up to now, only the IEC 62478 briefly mentions partial discharge measurements using electromagnetic sensors in gas-insulated substations (GIS). The IEC60270 standard provides a method...conference paper 2022
- document
-
Mier Escurra, C. (author), Mor, A. R. (author), Vaessen, P.T.M. (author)A recent investigation explored a new measuring concept used in partial discharges (PD) measurements in gas insulated substations (GIS), consisting of a magnetic loop antenna. The sensor's frequency response was characterized up to some tens of MHz. This paper proposes an improved version of the sensor with an extended bandwidth (BW) one...journal article 2021
- document
-
Mier Escurra, C. (author), Mor, A. R. (author)Gas insulated substations (GIS) have increased in the electric power system in recent years and is expected to continue increasing in the following years. The GIS has remarkable advantages over air insulated substation in offshore windfarms where the installation space is limited. The outlying location of the GIS demands a robust monitoring...conference paper 2021