Searched for: author%3A%22Mor%2C+A.+R.%22
(1 - 20 of 41)

Pages

document
Mier Escurra, C. (author), Mor, A. R. (author), Vaessen, P.T.M. (author), Lathouwers, A.G.A. (author)
One of the main difficulties in measuring partial discharges (PD) in gas-insulated substations (GIS) is the overlapping of pulses at the sensor's location, which distorts the pulse resolution and the charge estimation. This research presents a new method called “synergy,” which identifies and suppresses reflections using magnetic and electric...
journal article 2023
document
Wikkerink, D.P. (author), Mor, A. R. (author), Polinder, H. (author), Ross, Robert (author)
Ships can avoid to be detected by magnetic mines by reducing their magnetic signature with degaussing coils. Degaussing currents are provided by switched mode power supplies which impose a current ripple on top of the degaussing current. The ripple might be visible in the magnetic signature which would increase the detectability of the ship. A...
journal article 2022
document
Mier Escurra, C. (author), Mor, A. R. (author)
Recent research has found that Magnetic loop antennas can detect partial discharges (PD) in gas-insulated substations (GIS); however, unbalanced shielded loop (UBSL) antennas are affected by electric field coupling. This research proposes a balanced shielded loop (BSL) adapted for GIS PD sensing with different designs. The frequency response and...
conference paper 2022
document
Mier Escurra, C. (author), Mor, A. R. (author)
Partial discharges (PD) measurements provide an estimation of the severity of the insulation degradation; additionally, it is used as a unit of standardization. Up to now, only the IEC 62478 briefly mentions partial discharge measurements using electromagnetic sensors in gas-insulated substations (GIS). The IEC60270 standard provides a method...
conference paper 2022
document
Wikkerink, D.P. (author), Mor, A. R. (author), Polinder, H. (author), Ross, Robert (author)
Detection of the magnetic signature of ships can be avoided by using a degaussing system; a set of on-board copper coils that compensates for the magnetic signature. High temperature superconductors (HTS) are currently investigated as a replacement for copper degaussing coils. By using HTS, we have to deal with higher currents and therefore...
journal article 2022
document
Mier Escurra, C. (author), Mor, A. R. (author), Castro Heredia, L.C. (author), Vaessen, P.T.M. (author)
There are no accepted procedures that quantify the apparent charge of partial discharge (PD) in gas-insulated substations (GIS). This paper proposes a calibration method for PD charge estimation using unconventional electromagnetic sensors: a magnetic loop antenna (inductive coupler) and an electric antenna (capacitive coupler.) The...
journal article 2022
document
Abdul Madhar, S. (author), Mor, A. R. (author), Mraz, Petr (author), Ross, Robert (author)
This paper presents the investigation on surface discharge behavior of various dielectric samples under DC. It sequentially develops the knowledge base for the study and analysis of the partial discharge (PD) defect with the goal of PD defect identification under DC. In order to facilitate this, the material properties of the dielectric are...
journal article 2021
document
Mier Escurra, G.A. (author), Mor, A. R. (author), Castro Heredia, L.C. (author), Vaessen, P.T.M. (author)
Space charges are one of the main challenges facing the constantly increasing use of extruded high voltage direct current (HVDC) cables. The Pulsed Electro-Acoustic (PEA) method is one of the most common procedures for space charge measurements of insulation. One issue with the PEA method is distortion due to the crosstalk between the applied...
journal article 2021
document
Mier Escurra, G.A. (author), Mor, A. R. (author)
The Pulsed Electroacoustic Method is one of the most common methods for space charge measurements in solid dielectrics. This method involves applying a voltage pulse across the dielectric under test, which modifies the electrostatic force balance across the dielectric, creating an acoustic signal that can be measured externally. This work...
conference paper 2021
document
Mier Escurra, C. (author), Mor, A. R. (author), Vaessen, P.T.M. (author)
A recent investigation explored a new measuring concept used in partial discharges (PD) measurements in gas insulated substations (GIS), consisting of a magnetic loop antenna. The sensor's frequency response was characterized up to some tens of MHz. This paper proposes an improved version of the sensor with an extended bandwidth (BW) one...
journal article 2021
document
Mier Escurra, C. (author), Mor, A. R. (author)
Gas insulated substations (GIS) have increased in the electric power system in recent years and is expected to continue increasing in the following years. The GIS has remarkable advantages over air insulated substation in offshore windfarms where the installation space is limited. The outlying location of the GIS demands a robust monitoring...
conference paper 2021
document
Mor, A. R. (author), Muñoz Muñoz, F.A. (author), Castro Heredia, L.C. (author)
The authors wish to make the following erratum to this paper [1]: the summation symbol in the Equations (11) and (12) should be a product symbol. The corrected Equations (11) and (12) appear below: The authors apologize for any inconvenience caused and state that the scientific conclusions are unaffected. The original article has been updated...
journal article 2021
document
Abdul Madhar, S. (author), Brunner, Marc (author), Mor, A. R. (author), Mraz, Petr (author)
The discharge over dielectric interfaces popularly known as surface discharge is a very common defect type that is associated with its respective discharge pattern under AC voltages. However, the same designs behave differently under DC voltages leading up to erratic PD behavior. To understand the process of surface discharge an equivalent...
conference paper 2021
document
Abdul Madhar, S. (author), Mraz, Petr (author), Mor, A. R. (author), Ross, Robert (author)
This paper presents several approaches to the analysis of partial discharge (PD) data. Three common defects namely corona, surface and floating electrode are studied with the goal of defect identification under DC stress conditions. One of the major concerns with DC-PD testing, is its non-repetitive/erratic pulse pattern. This paper, however,...
journal article 2020
document
Muñoz Muñoz, F.A. (author), Mor, A. R. (author)
This paper presents a wavelet analysis technique together with support vector machines (SVM) to discriminate partial discharges (PD) from external disturbances (electromagnetic noise) in a GIS PD measuring system based on magnetic antennas. The technique uses the Cross Wavelet Transform (XWT) to process the PD signals and the external...
journal article 2020
document
Abdul Madhar, S. (author), Mraz, Petr (author), Mor, A. R. (author), Ross, Robert (author)
Corona is one of the most common forms of partial discharge (PD) occurring in high voltage (HV) energy systems. The corona mechanism in air is not exclusive to the field of energy applications but has also been widely studied by physicists to theorize mechanisms of charge transfer during the different phases of gas discharge. The phases of the...
journal article 2020
document
Castro Heredia, L.C. (author), Mor, A. R. (author), Wu, J. (author)
The problem of impaired data sets refers to data sets containing a vast majority of unwanted signals than signals of interest. With increased interest in partial discharge (PD) testing with arbitrary waveforms and transients, these kind of data sets are becoming more and more common. Traditional clustering techniques cannot be applied due to big...
journal article 2020
document
Mier Escurra, G.A. (author), Mor, A. R. (author), Vaessen, P.T.M. (author)
Nowadays, with the widespread use of High Voltage Direct Current (HVDC) cables in power systems, the measurements of space charges in full-size cables are becoming more relevant. One of the most common methods used for space charge measurements is the Pulsed Electro-Acoustic (PEA) method. This paper analyzes two factors that influence the...
journal article 2020
document
Morette, N. (author), Castro Heredia, L.C. (author), Ditchi, Thierry (author), Mor, A. R. (author), Oussar, Y. (author)
This paper tackles the problem of the classification of partial discharge (PD) and noise signals by applying unsupervised and semi-supervised learning methods. The first step in the proposed methodology is to prepare a set of classification features from the statistical moments of the distribution of the Wavelet detail coefficients extracted...
journal article 2020
document
Mor, A. R. (author), Muñoz Muñoz, F.A. (author), Castro Heredia, L.C. (author)
This paper describes a simplified model and a generic model of high-frequency current transformer (HFCT) sensors. By analyzing the models, a universal charge estimation method based on the double time integral of the measured voltage is inferred. The method is demonstrated to be valid irrespective of HFCT sensor, assuming that its transfer...
journal article 2020
Searched for: author%3A%22Mor%2C+A.+R.%22
(1 - 20 of 41)

Pages