Searched for: author:"Pertijs, M.A.P."
(1 - 20 of 20)
document
Janjic, Jovana (author), Tan, M. (author), Daeichin, V. (author), Noothout, E.C. (author), Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Beurskens, Robert H.S.H. (author), van Soest, G. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author), de Jong, N. (author)
Intravascular ultrasound is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking intravascular ultrasound (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2D array...
journal article 2018
document
Vlachogiannakis, G. (author), Pertijs, M.A.P. (author), Spirito, M. (author), de Vreede, L.C.N. (author)
A compact sensing pixel for the determination of the localized complex permittivity at microwave frequencies is proposed. Implemented in the 40-nm CMOS, the architecture comprises a square patch, interfaced to the material-under-test sample, that provides permittivity-dependent admittance. The patch admittance is read out by embedding the patch...
journal article 2018
document
Daeichin, V. (author), Bera, D. (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Chen, Z. (author), Chen, C. (author), Noothout, E.C. (author), Vos, H.J. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author), More Authors (author)
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a...
journal article 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Noothout, E.C. (author), Chang, Z.Y. (author), Tan, M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents a front-end application-specified integrated circuit (ASIC) integrated with a 2-D PZT matrix transducer that enables in-probe digitization with acceptable power dissipation for the next-generation endoscopic and catheter-based 3-D ultrasound imaging systems. To achieve power-efficient massively parallel analog-to-digital...
journal article 2018
document
Bera, D. (author), Van Den Adel, Franc (author), Radeljic-Jakic, Nikola (author), Lippe, Boris (author), Soozande, M. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), Kruizinga, P. (author), Daeichin, V. (author), Vos, H.J. (author), van der Steen, A.F.W. (author), Bosch, Johan G. (author), de Jong, N. (author)
We describe a 3-D multiline parallel beamforming scheme for real-time volumetric ultrasound imaging using a prototype matrix transesophageal echocardiography probe with diagonally diced elements and separated transmit and receive arrays. The elements in the smaller rectangular transmit array are directly wired to the ultrasound system. The...
journal article 2018
document
D'Urbino, Michele (author), Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Ponte, Jacco (author), Lippe, Boris (author), Pertijs, M.A.P. (author)
This paper presents a power- and area-efficient approach to digitizing the echo signals received by piezoelectric transducer elements, commonly used for ultrasound imaging. This technique utilizes such elements not only as sensors but also as the loop filter of an element-level δσ analog to digital converter (ADC). The receiver chain is thus...
journal article 2018
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author)
Typically, ultrasonic flow meters assume linear wave propagation. Nevertheless, if the transducers of an ultrasonic flow sensor excite a pressure wave with a high amplitude, nonlinear wave propagation effects become significant. The appearance of higher harmonics increases the bandwidth of the received signal, which may potentially lead to a...
conference paper 2018
document
Cai, Z. (author), van Veldhoven, Robert (author), Suy, Hilco (author), de Graaf, G. (author), Makinwa, K.A.A. (author), Pertijs, M.A.P. (author)
This paper presents a readout circuit for a carbon dioxide (COࠢ) sensor that measures the CO₂-dependent thermal time constant of a hot-wire transducer. The readout circuit periodically heats up the transducer and uses a phase-domain Δ Σ modulator to digitize the phase shift of the resulting...
journal article 2018
document
Chen, C. (author), Chen, Z. (author), Bera, Deep (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Chang, Z.Y. (author), Ponte, Jacco (author), Prins, Christian (author), Vos, H.J. (author), Bosch, J.G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
ASIC, implemented...
journal article 2017
document
Cai, Z. (author), Rueda Guerrero, Luis E. (author), Louwerse, Alexander Mattheus Robert (author), Suy, Hilco (author), van Veldhoven, Robert (author), Makinwa, K.A.A. (author), Pertijs, M.A.P. (author)
This paper reports a readout circuit capable of accurately measuring not only the resistance of a resistive transducer, but also the power dissipated in it, which is a critical parameter in thermal flow sensors or thermal-conductivity sensors. A front-end circuit, integrated in a standard CMOS technology, sets the voltage drop across the...
journal article 2017
document
Heidary Shalmany, S. (author), Merz, Matthias (author), Fekri, A. (author), Chang, Z.Y. (author), Hoofman, Romano J.O.M. (author), Pertijs, M.A.P. (author)
This paper demonstrates a micropower offset- and temperature-compensated smart pH sensor, intended for use in battery-powered RFID systems that monitor the quality of perishable products. Low operation power is essential in such systems to enable autonomous logging of environmental parameters, such as the pH level, over extended periods of time...
journal article 2017
document
Cai, Z. (author), van Veldhoven, Robert (author), Falepin, A (author), Suy, Hilco (author), Sterckx, E (author), Bitterlich, C. (author), Makinwa, K.A.A. (author), Pertijs, M.A.P. (author)
This paper reports a readout circuit for a resistive CO2 sensor, which operates by measuring the CO2-dependent thermal conductivity of air. A suspended hot-wire transducer, which acts both as a resistive heater and temperature sensor, exhibits a CO2-dependent heat loss to the surrounding air, allowing CO2 concentration to be derived from its...
journal article 2016
document
Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Pertijs, M.A.P. (author)
This paper presents a power- and area-efficient 9-channel LNA array for piezoelectric ultrasound transducers to enable real-time 3D imaging with miniature endoscopic and catheter-based probes. In view of the relatively low impedance of piezoelectric transducers, the LNA is implemented as a capacitive feedback voltage amplifier, rather than a...
conference paper 2015
document
Jiang, J. (author), Chang, Z.Y. (author), Pertijs, M.A.P. (author)
This paper presents an energy-efficient readout circuit for micro-machined resonant sensors. It operates by briefly exciting the sensor at a frequency close to its resonance frequency, after which resonance frequency and quality factor are determined from a single ring-down transient. The circuit employs an inverter-based trans-impedance...
journal article 2015
document
Zeng, Z. (author), Pertijs, M.A.P. (author), Karabacak, D.M. (author)
This paper presents an energy-efficient readout circuit for resonant sensors that operates based on a transient measurement method. The resonant sensor is driven at a frequency close to its resonance frequency by an excitation source that can be intermittently disconnected, causing the sensor to oscillate at its resonance frequency with...
journal article 2013
document
Aita, AL (author), Pertijs, M.A.P. (author), Makinwa, K.A.A. (author), Huijsing, J.H. (author), Meijer, G.C.M. (author)
In this paper, a low-power CMOS smart temperature sensor is presented. The temperature information extracted using substrate PNP transistors is digitized with a resolution of 0.03 °C using a precision switched-capacitor (SC) incremental
A/D converter. After batch calibration, an inaccuracy of ±0.25 °C (±3σ ) from −70 °C to 130 °C is...
journal article 2013
document
Pertijs, M.A.P. (author), Aita, AL (author), Makinwa, K.A.A. (author), Huijsing, J.H. (author)
Smart temperature sensors generally need to be trimmed to obtain measurement errors below ±2°C. The associated temperature calibration procedure is time consuming and therefore costly. This paper presents two, much faster, voltage calibration techniques. Both make use of the fact that a voltage proportional to absolute temperature (PTAT) can be...
journal article 2010
document
Pertijs, M.A.P. (author), Makinwa, K.A.A. (author), Huijsing, J.H. (author)
journal article 2005
document
Pertijs, M.A.P. (author), Niederkorn, A. (author), McKillop, B. (author), Bakker, A. (author), Huijsing, J.H. (author)
journal article 2005
document
Pertijs, M.A.P. (author), Meijer, G.C.M. (author), Huijsing, J.H. (author)
journal article 2004
Searched for: author:"Pertijs, M.A.P."