document
Bsat, S. (author), Yavari, S. (author), Munsch, M. (author), Valstar, E.R. (author), Zadpoor, A.A. (author)
Advanced additive manufacturing techniques such as electron beam melting (EBM), can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the...
journal article 2015
document
Van der Voort, P. (author), Pijls, B.G. (author), Nieuwenhuijse, M.J. (author), Jasper, J. (author), Fiocco, M. (author), Plevier, J.W.M. (author), Middeldorp, S. (author), Valstar, E.R. (author), Nelissen, R.G.H.H. (author)
Background and purpose — Few studies have addressed the association between early migration of femoral stems and late aseptic revision in total hip arthroplasty. We performed a meta-regression analysis on 2 parallel systematic reviews and meta-analyses to determine the association between early migration and late aseptic revision of femoral...
journal article 2015
document
Van IJsseldijk, E.A. (author), Lebel, B. (author), Stoel, B.C. (author), Valstar, E.R. (author), Gouzy, S. (author), Vielpeau, C. (author), Kaptein, B.L. (author)
Implant failure related to polyethylene wear remains an important issue in total knee arthroplasty. Polyethylene wear is usually assessed in vivo by measuring the remaining insert thickness on X-ray images of the knee. To reflect the amount of wear debris more accurately, a 3-dimensional overlap measurement has been suggested, which is based on...
journal article 2014
document
Valstar, E.R. (author)
public lecture 2013
document
Wolterbeek, N. (author), Garling, E.H. (author), Mertens, B.J. (author), Nelissen, R.G.H.H. (author), Valstar, E.R. (author)
Background The mobile-bearing variant of a single-radius design is assumed to provide more freedom of motion compared to the fixed-bearing variant because the insert does not restrict the natural movements of the femoral component. This would reduce the contact stresses and wear which in turn may have a positive effect on the fixation of the...
journal article 2012
document
Pijls, B.G. (author), Dekkers, O.M. (author), Middeldorp, S. (author), Valstar, E.R. (author), Van der Heide, H.J.L. (author), Van der Linden-Van der Zwaag, H.M.J. (author), Nelissen, R.G.H.H. (author)
Background: In the light of both the importance and large numbers of case series and cohort studies (observational studies) in orthopaedic literature, it is remarkable that there is currently no validated measurement tool to appraise their quality. A Delphi approach was used to develop a checklist for reporting quality, methodological quality...
journal article 2011
document
Wolterbeek, N. (author), Nelissen, R.G.H.H. (author), Valstar, E.R. (author)
Purpose: The aim of this study was to compare a broad range of total knee prostheses with different design parameters to determine whether in vivo kinematics was consistently related to design. The hypothesis was that there are no clear recognizable differences in in vivo kinematics between different design parameters or prostheses. Methods: At...
journal article 2011