Searched for: subject%3A%22ASIC%22
(1 - 20 of 26)

Pages

document
Hopf, Y.M. (author)
This thesis describes the design of application-specific integrated circuits (ASICs) for high-frame-rate 3D intracardiac echocardiography (ICE) probes. The work follows the whole process from the analysis of the application to the testing of a prototype with all envisioned functionality. It starts with the evaluation of the main challenges posed...
doctoral thesis 2023
document
van Willigen, D.M. (author)
This thesis describes the design, prototyping and evaluation of matrix-based clamp-on ultrasonic flow meters. Several new measurement techniques are presented as well as an Application-Specific Integrated Circuit (ASIC) designed for accurate measurement of flow velocity with matrix transducers.<br/><br/>The influence of circuit topologies on the...
doctoral thesis 2022
document
Tan, M. (author)
This thesis describes the design, prototyping and experimental evaluation of transceiver ASICs (application-specific integrated circuits) for catheter-based ultrasound probes and wearable ultrasound patches. To reduce the loading effect of micro-coaxial cables in an ICE probe based on capacitive micro-machined ultrasound transducers (CMUTs), an...
doctoral thesis 2022
document
Ding, Xin (author)
This thesis discusses the architecture, circuit implementation and the simulation results of a cable driver for ultrasound imaging. This design is capable of providing higher bandwidth, better dynamic range, wider output swing, and ideal biasing voltage at the output terminal. <br/>The driver design starts from the analysis and simulation of the...
master thesis 2022
document
Overwater, R.W.J. (author), Babaie, M. (author), Sebastiano, F. (author)
Quantum error correction (QEC) is required in quantum computers to mitigate the effect of errors on physical qubits. When adopting a QEC scheme based on surface codes, error decoding is the most computationally expensive task in the classical electronic back-end. Decoders employing neural networks (NN) are well-suited for this task but their...
journal article 2022
document
Simoes dos Santos, D. (author), Fool, F. (author), Mozaffarzadeh, M. (author), Shabanimotlagh, M. (author), Noothout, E.C. (author), Kim, T. (author), Rozsa, N.N.M. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for...
journal article 2022
document
Colas, Quorentin (author), Bantignies, Claire (author), Perroteau, Marie (author), Porcher, Nicolas (author), Vassal, Steeven (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
Three-dimensional ultrasound has initially been used to address volumetric imaging for diagnostic purposes and represents the leading-edge technological orientation in both transducer and IC (integrated circuit) architecture and design. However, new applications are coming up like biomarker measurements, preoperative navigation, real time...
conference paper 2022
document
Hopf, Y.M. (author), Ossenkoppele, Boudewine W. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The...
journal article 2022
document
Veselka, David (author)
Implantable Medical Devices (IMDs) are deployed in patients to treat a range of medical conditions. Technological advancements have enabled manufacturers to fit IMDs with specialized hardware that accelerates compute-intensive medical therapies next to a software-run host processor. However, mostly hardware acceleration is found in the form of...
master thesis 2021
document
van Willigen, D.M. (author), Kang, E. (author), Janjic, Jovana (author), Noothout, E.C. (author), Chang, Z.Y. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This article presents an application-specific integrated circuit (ASIC) designed for intra-vascular ultrasound imaging that interfaces 64 piezoelectric transducer elements to an imaging system using a single micro-coaxial cable. Thus, it allows a single-element transducer to be replaced by a transducer array to enable 3-D imaging. The 1.5-mm...
journal article 2021
document
Simoes dos Santos, D. (author), Fool, F. (author), Kim, Taehoon (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Pertijs, M.A.P. (author), Verweij, M.D. (author), de Jong, N. (author)
Over the past decades, real-time three-dimensional (3D) medical ultrasound has attracted much attention since it enables clinicians to diagnose more accurately. This calls for ultrasound matrix transducers with a large number of elements, which can be interfaced with an application-specific integrated circuit (ASIC) for data reduction. An...
conference paper 2021
document
Kim, Taehoon (author), Fool, F. (author), Simoes dos Santos, D. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a...
journal article 2021
document
Vijayakumar, Arvind (author)
Capacitive micromachined ultrasonic transducer (CMUT) technology has been considered as a promising alternative for the conventional piezo electric-based technology in ultrasound imaging systems. Its potential advantages include better image quality, higher operational frequency, and ease of fabrication and<br/>integration with CMOS read-out...
master thesis 2020
document
Kang, E. (author), Tan, M. (author), An, J. (author), Chang, Z.Y. (author), Vince, Philippe (author), Sénégond, Nicolas (author), Mateo, Tony (author), Meynier, Cyril (author), Pertijs, M.A.P. (author)
This article presents a low-noise transimpedance amplifier (TIA) designed for miniature ultrasound probes. It provides continuously variable gain to compensate for the time-dependent attenuation of the received echo signal. This time-gain compensation (TGC) compresses the echo-signal dynamic range (DR) while avoiding imaging artifacts...
journal article 2020
document
van Willigen, D.M. (author), Mozaffarzadeh, M. (author), Noothout, E.C. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author), Daeichin, V. (author)
This paper presents the integration steps towards a prototype forward-looking intra-vascular ultrasound probe. An ASIC (Application Specific Integrated Circuit) is laser cut to create a 1.6mm circular shaped die that can be integrated at the tip of a small catheter. The ASIC is designed such that it can be used to transmit and receive on 64...
conference paper 2019
document
Jiang, Qiyou (author)
This work presents a low-noise amplifier (LNA) for ultrasound imaging with built-in continuous time-gain compensation (TGC), which compensates for the time-dependent attenuation of the received echo signal and thus significantly reduces its dynamic range (DR). The proposed design combines the LNA and TGC functions in a single variable-gain...
master thesis 2019
document
Kang, E. (author), Ding, Q. (author), Shabanimotlagh, M. (author), Kruizinga, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, J.W. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) designed for 3-D ultrasonic imaging of the carotid artery. This application calls for an array of thousands of ultrasonic transducer elements, far exceeding the number of channels of conventional imaging systems. The 3.6 x 6.8 mm&amp;#x00B2; ASIC...
journal article 2018
document
Rezaeiyan, Y. (author), Zamani, M. (author), Shoaei, Omid (author), Serdijn, W.A. (author)
A low-power mixed-signal IC for implantable pacemakers is presented. The proposed system features three independent intracardiac signal readout channels with pulse-width-modulated outputs. Also, the proposed system is capable of measuring the amplitude and phase of the bioimpedance with pulse-width-modulated outputs for use in rate adaptive...
journal article 2018
document
Janjic, Jovana (author), Tan, M. (author), Daeichin, V. (author), Noothout, E.C. (author), Chen, C. (author), Chen, Z. (author), Chang, Z.Y. (author), Beurskens, Robert H.S.H. (author), van Soest, G. (author), van der Steen, A.F.W. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author), de Jong, N. (author)
Intravascular ultrasound is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking intravascular ultrasound (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2D array...
journal article 2018
document
Daeichin, V. (author), Bera, D. (author), Raghunathan, S.B. (author), Shabanimotlagh, M. (author), Chen, Z. (author), Chen, C. (author), Noothout, E.C. (author), Vos, H.J. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a...
journal article 2018
Searched for: subject%3A%22ASIC%22
(1 - 20 of 26)

Pages