Searched for: subject:"Lenses"
(1 - 15 of 15)
document
López-Marín, Antonio (author), Springeling, Geert (author), Beurskens, Robert (author), Van Beusekom, Heleen (author), van der Steen, A.F.W. (author), Koch, Arjun D. (author), Bouma, Brett E. (author), Huber, Robert A. (author), Van Soest, Gijs (author), Wang, Tianshi (author)
In this study, we demonstrate a 12x36 mm motorized capsule for OCT imaging of the esophagus. The capsule produces unobstructed images by using a distal reflector design, thus avoiding shadow caused by the motor wires. The motor synchronous control enables three working modes: circumferential imaging, angular sector imaging and accurate beam...
conference paper 2020
document
Abreu Vieira Viula, R.J. (author), Hordijk, G.J. (author)
The calculation of field-of-view luminance based metrics for visual discomfort from glare evaluation in real scenes via HDR (High Dynamic Range) luminance capture does generally require the use of wide view fisheye lenses. This paper presents an easy to implement and low-cost method to estimate a fisheye lens’ total field-of view and projection...
conference paper 2019
document
van Berkel, S.L. (author), Malotaux, E.S. (author), Cavallo, D. (author), Spirito, M. (author), Neto, A. (author), Llombart, Nuria (author)
The optical performance of a wideband double bowtie slot antenna, implemented in 28nm CMOS technology, is evaluated. The antenna serves as a verification antenna for an uncooled single-pixel radiometer operating from 200 GHz to 600 GHz. The performance is evaluated in terms of radiometric pattern that is derived from the measured radiation...
conference paper 2018
document
Bueno Lopez, J. (author), Yurduseven, O. (author), Llombart, Nuria (author), Yates, S.J.C. (author), Neto, A. (author), Baselmans, J.J.A. (author)
This contribution presents the design and sub-mm wave measurements of a wideband dual polarized leaky lens antenna coupled to kinetic inductance detector (KIDs) to be specifically used for tightly spaced focal plane arrays. The antenna is planar and composed by two crossed slots, fed by two orthogonal coplanar waveguide (CPW) lines. In...
conference paper 2017
document
Strauch, M. (author), Shao, Y. (author), Bociort, F. (author), Urbach, H.P. (author)
The increased usage of liquid lenses motivates us to investigate surface waves on the liquid's surface. During fast focal switching, the surface waves decrease the imaging quality. We propose a model that describes the surface modes appearing on a liquid lens and predicts the resonance frequencies. The effects of those surface modes on a...
journal article 2017
document
Dabironezare, S.O. (author), Neto, A. (author), Llombart Juan, N. (author)
Passive imaging cameras at sub-millimeter wave-lengths are currently entering a new era with the development of large format arrays of direct detectors. Several of these arrays are being developed with bare absorbing meshes without any antenna coupling (lens or horn) structures. This paper uses a spectral electromagnetic model to analyze the...
conference paper 2017
document
Garufo, A. (author), Carluccio, G. (author), Freeman, Joshua R. (author), Bacon, David R. (author), Llombart Juan, N. (author), Davies, Alexander G. (author), Neto, A. (author)
In this paper a rigorous electromagnetic characterization of the setup for measuring the THz power radiated by pulsed photoconductive antenna is discussed. Such characterization is expressed in terms of efficiencies which quantify how much power is lost in the coupling between the various components involved in the measurement setup. The...
conference paper 2017
document
van Berkel, S.L. (author), Malotaux, E.S. (author), Cavallo, D. (author), Spirito, M. (author), Neto, A. (author), Llombart Juan, N. (author)
The design and performance analysis are presented for a passive uncooled radiometer pixel suitable for integration in 28 nm CMOS technology. In the configuration a single wideband antenna, operating from 200 GHz to 600 GHz, is connected to a pn-junction diode. Including the antenna-detector impedance mismatch, the detector shows an average NEP...
conference paper 2017
document
Yurduseven, O. (author), Bosma, S. (author), Endo, A. (author), Neto, A. (author), Llombart Juan, N. (author)
DESHIMA (Deep Spectroscopic High-redshift Mapper) is an instrument aiming at efficiently making spectroscopic redshift measurements of sub-mm wave galaxies (SMGs), thereby providing about the formation and the evolution of stars and galaxies. The aim of this work is to provide a preliminary study into the design of a wideband leaky lens antenna...
conference paper 2017
document
Llombart Juan, N. (author), Gandini, E. (author), Tamminen, A. (author), Luukanen, A. (author)
The aim of the European project CONSORTIS is the development of a walk-by imaging system for concealed object detections working at submillimetre-wave frequencies. This imager will allow to image a full body at two frequency bands with high sensitivity (<;1K) and large frame rate (10Hz). The imager relies on a large focal plane array with...
conference paper 2016
document
Subrahmanian, E. (author), Reich, Y. (author), Smoders, F. (author), Meijer, S.A. (author)
Designing is a multi-dimensional phenomenon and is difficult to describe through one disciplinary research lens only. This paper uses a framework within which multiple theories of designing could be informed of their role and explanatory power. The Product space and Social Space framework describes the scope of designing activities and it allows...
conference paper 2011
document
Mohammadi-Gheidari, A. (author), Hagen, C.W. (author), Kruit, P. (author)
The authors present the first results obtained with their multibeam scanning electron microscope. For the first time, they were able to image 196 (array of 14×14) focused beams of a multielectron beam source on a specimen using single beam scanning electron microscope (SEM) optics. The system consists of an FEI Novanano 200 SEM optics column...
journal article 2010
document
Zhang, W. (author), Khosropanah, P. (author), Gao, J.R. (author), Bansal, T. (author), Klapwijk, T.M. (author), Miao, W. (author), Shi, S.C. (author)
We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. Terahertz (THz) radiation is quasioptically coupled to a HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated...
journal article 2010
document
Hagen, C.W. (author), Kruit, P. (author)
The authors have analyzed how much current can be obtained in the probe of an optimized two-lens focused ion beam (FIB) system. This becomes relevant, as systems become available that have the potential to image and/or fabricate structures smaller than 10 nm. The probe current versus probe size curves were calculated for a commercial gallium-FIB...
journal article 2009
document
Van Bruggen, M.J. (author), Van Someren, B. (author), Kruit, P. (author)
Micro-Einzel lenses always suffer from chromatic and spherical aberration, even when the electron beam is exactly on the optical axis of the lens. When the inclination of the electron beam with respect to the lens axis increases, additional effects such as coma, astigmatism, and defocus start to dominate. An example of inclined electron beams in...
journal article 2009
Searched for: subject:"Lenses"
(1 - 15 of 15)