Constantly growing amount of renewables and storage installed in the power system results in an increased interest in the power transfer under Direct Current (DC), especially in the low and medium voltage (LV and MV) networks. This is valid for both already existing as well as ...

In recent years, the architecture of the power system has been the subject of a major change. The commonly known structure with centralized generation and one directional power flow, gives gradually the place to the new concept of the power network where both the energy generator ...

Original and pyrometamorphical altered Bentheimer sandstone

Petrophysical properties, surface and dielectric behavior

Bentheimer sandstone is a quartz-rich permeable hard sedimentary rock used for core flooding experiments. When fired to stabilize clays (subjected to high temperatures), pyrometamorphical phase changes induce texture and pore framework alteration. As a consequence the new dielect ...
The transformers are very complex devices, consisting of different subcomponents e.g. winding, tap changer, bushing etc. During operation, all of the subcomponents are stressed and subjected to aging. When the aging reaches certain level, the subcomponent may fail. By application ...
An on-load tap changer (OLTC) is prone to many different defects and degradation mechanisms due to its continuous operation under load condition. A high load current and high operation temperature accelerate the process of contact wear. Contacts erode due to the fact that under c ...
Diagnostics of HV power cables are playing an important role in the meaning of two aspects: 1) on-site diagnostic of new installation, where a commissioning test has to prove the absence of any defects in the cable insulation and accessories, after transportation and installation ...
Resistance measurements on power transformers are offline diagnostic methods that are performed without opening the transformer main tank. In case the power transformer is equipped with an on-load tap changer (OLTC), this resistance measurement can be used to find degradation and ...
This paper discusses the recently developed analysis method for service aged power transformers equipped with an OLTC: dynamic resistance measurements (DRM). Because the on-load tap changer contributes to many power transformer failures the emphasis is on OLTC diagnosis. Off-line ...
Diagnostics of HV power cables are playing an important role in the meaning of two aspects: 1) on-site diagnostic of new installation, where a commissioning test has to prove the absence of any defects in the cable insulation and accessories, after transportation and installation ...

Contributed

In the transmission and distribution network of the future, there is expected to be a mix of both Alternating Current (AC) and Direct Current (DC). In the high voltage division owing to technical and economic aspects, there is a wider use of High Voltage Direct Current (HVDC) ins ...