G

Geert

18 records found

Authored

Four-dimensional ultrasound imaging of complex biological systems such as the brain is technically challenging because of the spatiotemporal sampling requirements. We present computational ultrasound imaging (cUSi), an imaging method that uses complex ultrasound fields that ca ...

Multimodal intravascular ultrasound and photoacoustic (IVUS/PA) imaging is a promising diagnostic tool for cardiovascular diseases like atherosclerosis. IVUS/PA catheters typically require two independent transducers due to different frequency requirements, potentially increasing ...

In this study, we demonstrate a 12x36 mm motorized capsule for OCT imaging of the esophagus. The capsule produces unobstructed images by using a distal reflector design, thus avoiding shadow caused by the motor wires. The motor synchronous control enables three working modes: ...

In interventional electrophysiology, catheter-based radiofrequency (RF) ablation procedures restore cardiac heart rhythm by interrupting aberrant conduction paths. Real-time feedback on lesion formation and post-treatment lesion assessment could overcome procedural challenges ...

We demonstrate a tethered motorized capsule for unobstructed optical coherence tomography (OCT) imaging of the esophagus. By using a distal reflector design, we avoided the common shadow artifact induced by the motor wires. A synchronous driving technique features three types ...

Prospective identification of lipid-rich vulnerable plaque has remained an elusive goal. Intravascular photoacoustics, a hybrid optical and ultrasonic technology, was developed as a tool for lipid-rich plaque imaging. Here, we present the first in vivo images of lipid-rich cor ...

Photoacoustic signals can have very large bandwidth and large dynamic range. With appropriate electrical impedance matching, off-resonance PVDF transducers offer the bandwidth and sensitivity to fully capture these signals. Minimizing pitch and kerf in ultrasound transducer to im ...

Atrial fibrillation is a cardiac arrhythmia stemming from abnormal electrical conduction/impulse formation in the atria. To restore cardiac rhythm an RF ablation (RFA) procedure, interrupting aberrant electrical patterns, is commonly performed. One way of improving the procedu ...

We present a form of acoustic microscopy, called Structured Ultrasound Microscopy (SUM). It creates a volumetric image by recording reflected echoes of ultrasound waves with a structured phase front using a moving single-element transducer and computational reconstruction. A p ...

Intravascular photoacoustic/ultrasound imaging (IVPA/US) can image the structure and composition of atherosclerotic lesions identifying lipid-rich plaques ex vivo and in vivo. In the literature, multiple IVPA/US catheter designs were presented and validated both in ex-vivo mod ...

3D ultrasound (US) requires expensive transducers comprising thousands of elements and complicated hardware. This complexity originates from the classical idea on spatial sampling requirements for US imaging. The discovery of compressive sensing allows to ease this sampling const ...
Photoacoustic imaging couples the chemical specificity of optical absorption with the viewing depth of ultrasound. Systems based on linear array transducers have the versatility to be applied in various (pre-) clinical scenarios but face a trade-off between viewing depth and imag ...
Three-dimensional ultrasound is a powerful imaging technique, but it requires thousands of sensors and complex hardware. Very recently, the discovery of compressive sensing has shown that the signal structure can be exploited to reduce the burden posed by traditional sensing requ ...

Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets ...

This paper presents a custom-designed single-cable readout IC for the reception of the broadband photoacoustic (PA) signal in intravascular photoacoustic (IVPA) imaging. The readout IC is intended for direct integration behind a broadband polyvinylidene fluoride (PVDF) transducer ...