Quantifying Renal Perfusion at 3 T and 0.6 T using Arterial Spin Labeling MRI

Master Thesis (2025)
Author(s)

W.B.S. Deen (TU Delft - Mechanical Engineering)

Contributor(s)

R.F. Remis – Mentor (TU Delft - Tera-Hertz Sensing)

S.D. Weingärtner – Graduation committee member (TU Delft - ImPhys/Computational Imaging)

M. Bozic – Graduation committee member (TU Delft - ImPhys/Weingärtner group)

Faculty
Mechanical Engineering
More Info
expand_more
Publication Year
2025
Language
English
Graduation Date
12-11-2025
Awarding Institution
Delft University of Technology
Programme
['Biomedical Engineering | Medical Devices']
Faculty
Mechanical Engineering
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Objective: The aim of this project is to quantify renal perfusion at 3 T with arterial spin labeling (ASL) images and to evaluate the feasibility of this measurement at 0.6 T.

Background: Chronic kidney disease (CKD) affects over one in ten individuals worldwide and has a high mortality rate. As renal microvascular dysfunction plays a key role in CKD progression, accurate and non-invasive quantification of renal perfusion is valuable. ASL magnetic resonance imaging (MRI) enables the measurement of renal perfusion without exogenous contrast agents and has been validated at 1.5 T and 3 T. However, its feasibility at 0.6 T has not yet been investigated.

Methodology: Data from the NEO-2 study acquired at 3 T was analyzed using a pipeline that included image registration, segmentation, and quantitative perfusion mapping. Midfield scanners have a lower signal-to-noise ratio and altered relaxation times. Therefore, the existing renal ASL sequence used in 3 T was adjusted. The sequence parameters that were modified included the repetition time (TR), the number of control–label pairs, voxel size, post-label delay (PLD), and background suppression (BGS) pulse timings. After choosing the optimal parameters, a healthy volunteer was scanned back-to-back at both field strengths for direct comparison.

Results: At 3~T, cortical perfusion values ranged between 180 and 286 mL/100g/min, consistent with literature. Optimal parameters at 0.6 T were: TR = 4000 ms, 25 control–label pairs, in-plane resolution of 4×4 mm^2, slice thickness of 10 mm, and PLD = 1400 ms with BGS pulses at 700 & 1100 ms. With these settings applied at 0.6 T, the cortical perfusion values were 215.34 ± 67.92 and 236.80 ± 66.33 mL/100 g/min in the left and right cortex, respectively. Using the 3 T acquisition protocol, the corresponding values were 241.89 ± 76.55 and 250.75 ± 70.82 mL/100g/min, respectively. Values at 3 T were approximately 5–10% higher.

Conclusion: The results show that renal ASL at 0.6~T can produce quantitative perfusion estimates that are similar to those at 3 T.

Files

Thesis_Willemijn_Deen.pdf
(pdf | 5.89 Mb)
License info not available