Print Email Facebook Twitter US Army Centrifuge: Progressive collapse testing of a 4-story reinforced concrete structure at 1/18-Scale Part of: Eurofuge 2012· list the conference papers Title US Army Centrifuge: Progressive collapse testing of a 4-story reinforced concrete structure at 1/18-Scale Author Vanadit-Ellis, W. Gran, J.K. Vaughan, D. Date 2012-06-05 Abstract A 1/18-scale model of a 4-story reinforced concrete structure was tested at 18 g in the US Army Centrifuge to support the development of computational modeling of progressive collapse of multi-story buildings. The model structure was 4 bays long and 3 bays wide with column spacing about 33 cm in each directions and story height of 20.3 cm. Three columns around one corner at the 1st story were explosively removed while the model was spinning in the centrifuge at 18 g. The column removal resulted in complete collapse the bays above those columns but collapse did not progress to the rest of the structure. Subject centrifugeprogressive collapseconcrete structure To reference this document use: https://doi.org/10.4233/uuid:5ccd8844-1ca9-49f2-931b-eb9d9bf9234d Part of collection Conference proceedings Document type conference paper Rights (c) 2012 Vanadit-Ellis, W.; Gran, J.K.; Vaughan, D. Files PDF Vanadit-Ellis-US_Army_Cen ... -scale.pdf 1.01 MB Close viewer /islandora/object/uuid:5ccd8844-1ca9-49f2-931b-eb9d9bf9234d/datastream/OBJ/view