AS

Andreas Schulze- Bonhage

info

Please Note

2 records found

Journal article (2022) - J.A. Bilbao Nieva, E. Lourens, Andreas Schulze- Bonhage, Lisa Ziegler
Wind turbine towers are subjected to highly varying internal loads, characterized by large uncertainty. The uncertainty stems from many factors, including what the actual wind fields experienced over time will be, modeling uncertainties given the various operational states of the turbine with and without controller interaction, the influence of aerodynamic damping, and so forth. To monitor the true experienced loading and assess the fatigue, strain sensors can be installed at fatigue-critical locations on the turbine structure. A more cost-effective and practical solution is to predict the strain response of the structure based only on a number of acceleration measurements. In this contribution, an approach is followed where the dynamic strains in an existing onshore wind turbine tower are predicted using a Gaussian process latent force model. By employing this model, both the applied dynamic loading and strain response are estimated based on the acceleration data. The predicted dynamic strains are validated using strain gauges installed near the bottom of the tower. Fatigue is subsequently assessed by comparing the damage equivalent loads calculated with the predicted as opposed to the measured strains. The results confirm the usefulness of the method for continuous tracking of fatigue life consumption in onshore wind turbine towers. ...

Added value to an EEG-based detector using limited channels

Journal article (2021) - Kaat Vandecasteele, Thomas De Cooman, Wim Van Paesschen , Borbála Hunyadi, Christos Chatzichristos, Evy Cleeren, Lauren Swinnen, Jaiver Macea Ortiz, Sabine Van Huffel, Matthias Dümpelmann, Andreas Schulze- Bonhage, Maarten De Vos
Objective: Wearable seizure detection devices could provide more reliable seizure documentation outside the hospital compared to seizure self-reporting by patients, which is the current standard. Previously, during the SeizeIT1 project, we studied seizure detection based on behind-the-ear electroencephalography (EEG). However, the obtained sensitivities were too low for practical use, because not all seizures are associated with typical ictal EEG patterns. Therefore, in this paper, we aim to develop a multimodal automated seizure detection algorithm integrating behind-the-ear EEG and electrocardiography (ECG) for detecting focal seizures. In this framework, we quantified the added value of ECG to behind-the-ear EEG. Methods: This study analyzed three multicenter databases consisting of 135 patients having focal epilepsy and a total of 896 seizures. A patient-specific multimodal automated seizure detection algorithm was developed using behind-the-ear/temporal EEG and single-lead ECG. The EEG and ECG data were processed separately using machine learning methods. A late integration approach was applied for fusing those predictions. Results: The multimodal algorithm outperformed the EEG-based algorithm in two of three databases, with an increase of 11% and 8% in sensitivity for the same false alarm rate. Significance: ECG can be of added value to an EEG-based seizure detection algorithm using only behind-the-ear/temporal lobe electrodes for patients with focal epilepsy. ...