DE

Denise Eygendaal

info

Please Note

5 records found

Journal article (2026) - Derek F.R. van Loon, Eline M. van Es, Mark F. Siemensma, Denise Eygendaal, Filip Stockmans, H.E.J. Veeger, Joost W. Colaris
Background – Despite the clinical relevance of forearm fractures and malunions and the impact of a functional limitation, the link between forearm malalignment and limited pronation and supination remains poorly understood and still relies on anatomical alignment expressed as angulation. Using recently developed technologies, mechanisms that limit function can be automatically detected by modeling individual forearm kinematics using three-dimensional (3D) bone models of the radius and ulna.Questions/purposes – We evaluated the accuracy of a personalized 3D kinematic model to identify limitations in forearm rotation in pronation and supination and to answer the following questions: (1) How accurately does the model-predicted ROM agree with the corresponding clinical measurements? (2) How accurately does the model classify malunited forearms according to the presence of clinically relevant functional limitations, defined as a range of pronation or supination less than 50°? (3) What is the frequency at which the model detects bone impingement and central band block during pronation and supination?Methods – This retrospective study evaluated a diagnostic model using the preoperative CT scans of 45 patients with unilateral diaphyseal forearm malunions, all of whom underwent corrective osteotomy due to a clinically relevant limitation in pronation or supination function. In all, 53% (24) of patients were male; the mean ± SD age at the time of the CT scan was 16 ± 6 years, and the mean time since the original trauma was 6 ± 5 years. Twenty patients had a clinically relevant loss of pronation, 15 patients had a loss of supination, and 10 patients had a loss of both. We generated 3D bone models with landmarks to simulate forearm rotation in 5° steps from 100° of pronation to 100° of supination. Two mechanisms that limit function after diaphyseal malunions—bone impingement and central band blockage—were identified in the simulation, resulting in a predicted ROM. For the first study question, differences between clinical and predicted function were expressed as mean absolute error, root mean square error, and mean error to illustrate typical error size, penalize outliers, and quantify the direction of error deviation, respectively. Acceptable errors were around 15°, comparable to the range seen in clinical measurements. For question two, clinical measurements and predictions were dichotomized based on a threshold of 50°. Accuracy, sensitivity, specificity, positive and negative predictive values, and the area under the receiver operating characteristic (ROC) curve for detecting clinically relevant limitations were calculated separately for pronation and supination. Acceptable diagnostic values should be above 60%, which is normal for angulation measurements. For question three, the blocking mechanisms detected during the simulation were counted.Results – Mean absolute errors between prediction and clinical measurement for pronation, supination, and ROM were 19°, 23°, and 22°, respectively. Root mean square errors were 22° for pronation, 28° for supination, and 28° for ROM. Mean errors were 3° for pronation, 1° for supination, and 5° for ROM. Errors were substantially higher than the clinical measurement uncertainty, with some outliers. Accuracy for finding a relevant pronation or supination limitation was 91% and 82%, respectively. Diagnostic values for detecting pronation limitations were 91% for accuracy, 87% for sensitivity, 100% for specificity, 79% for negative predictive value, and 100% for positive predictive value. For supination, the values were 82% for accuracy, 84% for sensitivity, 80% for specificity, 80% for negative predictive value, and 84% for positive predictive value. Area under the curve values were 0.97 (95% confidence interval [CI] 0.93 to 1) for detecting pronation limitations and 0.93 (95% CI 0.87 to 1) for supination limitations. These values are higher than those reported by studies using angulation thresholds. Bone impingement was mainly seen during pronation, and a central band block was the most common reason for a supination limitation.Conclusion – Individualized kinematic modeling of forearm malunions reliably detects clinically relevant limitations of forearm rotation without requiring dynamic imaging. Because of simplifications on the exact location and status of the central band and the neutral position of the forearm, exact ROM prediction is not possibleClinical Relevance – This study represents an important step toward functional rather than anatomical evaluation of forearm anatomy and correction of malunited forearm fractures. The next step would be to use the model in preoperative planning optimization, focusing on functional outcomes rather than purely anatomical correction. Given the model’s high diagnostic accuracy, personalized 3D kinematic modeling has potential as a decision tool for determining whether a forearm fracture should undergo operative treatment or whether it can be managed nonoperatively. However, challenges regarding fracture remodeling and stability in a cast, along with low-dose 3D imaging, must be addressed. ...
Journal article (2025) - Derek F.R. van Loon, Mark F. Siemensma, Eline M. van Es, Denise Eygendaal, H.E.J. Veeger, Joost W. Colaris
Background: Dynamic medical imaging can determine the cause of rotational impairment in the forearm. However, it has drawbacks depending on the image modality used, related to radiation dose, the need for specialized equipment, and the labor intensity involved in the analysis. Because the forearm rotation axis is static, we hypothesize that an axis based on bony landmarks is comparable to an axis calculated from dynamic imaging. Methods: Eight post-mortem human forearms were scanned using CT in seven rotational positions from maximum supination to maximum pronation. Three rotation axes were calculated: the landmark, average helical, and circle fit axes. The primary outcome is the difference between the axes expressed as the angle and the minimal distance between them. Secondary outcomes are the orientation errors when modeling pose using the three found axes. Findings: The mean difference between the landmark and average helical axes was 0.38 degrees and 0.51 mm. The mean difference between the landmark and circle fit axes was 0.40 degrees and 0.51 mm. When modeling the pose of the radius using one of the three axes, the difference between the modeled radius and the scanned radius was in each direction below 2 mm and 1 degree. Interpretation: The rotation axis of the forearm can be accurately calculated using automatically placed bony landmarks. These findings indicate that determining the forearm rotation axis does not require multiple static images or dynamic imaging. This knowledge should be applied to clinical data to assess its applicability in practice. ...
Journal article (2024) - Derek F.R. van Loon, Eline M. van Es, Denise Eygendaal, H.E.J. Veeger, Joost W. Colaris
Background: For bone morphology and biomechanics analysis, landmarks are essential to define position, orientation, and shape. These landmarks define bone and joint coordinate systems and are widely used in these research fields. Currently, no method is known for automatically identifying landmarks on virtual 3D bone models of the radius and ulna. This paper proposes a knowledge-based method for locating landmarks and calculating a coordinate system for the radius, ulna, and combined forearm bones, which is essential for measuring forearm function. This method does not rely on pre-labeled data. Validation: The algorithm is validated by comparing the landmarks placed by the algorithm with the mean position of landmarks placed by a group of experts on cadaveric specimens regarding distance and orientation. Results: The median Euclidean distance differences between all the automated and reference landmarks range from 0.4 to 1.8 millimeters. The median angular differences of the coordinate system of the radius and ulna range from -1.4 to 0.6 degrees. The forearm coordinate system's median errors range from -0.2 to 2.0 degrees. The median error in calculating the rotational position of the radius relative to the ulna is 1.8 degrees. Conclusion: The automatic method's applicability depends on the use context and desired accuracy. However, the current method is a validated first step in the automatic analysis of the three-dimensional forearm anatomy. ...
Book chapter (2022) - B. van Trigt, Marco J.M. Hoozemans, Denise Eygendaal, H.E.J. Veeger
Journal article (2018) - Nick F.J. Hilgersom, Tim Horeman-Franse, Ronald L.A.W. Bleys, Denise Eygendaal, Michel P.J. van den Bekerom, Gabriëlle J.M. Tuijthof
Background: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation. The purpose of this study was to determine the force magnitude and force direction used by experts during arthroscopic elbow navigation in cadaveric specimens and assess their applicability in elbow arthroscopy training. Methods: Two cadaveric elbows were mounted on a Force Measurement Table (FMT) that allowed 3-dimensional measurements (x-, y-, and z-plane) of the forces exerted on the elbow. Five experts in elbow arthroscopy performed arthroscopic navigation once in each of two cadaveric elbows, navigating through the posterior, posterolateral and anterior compartment in a standardized fashion with visualization of three to four anatomic landmarks per compartment. The total absolute force (Fabs) and force direction exerted (α and β) on the elbow during arthroscopy were recorded. α being the angle in the horizontal plane and β being the angle in the vertical plane. The 10th–90th percentiles of the data were used to set threshold levels for training. Results: The median Fabs was 24 N (19 N – 30 N), 27 N (20 N – 33 N) and 29 N (23 N – 32 N) for the posterior, posterolateral and anterior compartment, respectively. The median α was - 29° (- 55° – 5°), - 23° (- 56° – -1°) and 4° (- 22° – -18°) for the posterior, posterolateral and anterior compartment, respectively. The median β was - 71° (- 80° – -65°), - 76° (- 86° – -69°) and - 75° (- 81° – -71°) for the posterior, posterolateral and anterior compartment, respectively. Conclusion: Expert data on force magnitude and force direction exerted on the elbow during arthroscopic navigation in cadaveric specimens were collected. The proposed maximum allowable force of 30 N (smallest 90th percentile of Fabs) exerted on the elbow tissue, and the 10th–90th percentile range of the force directions (α and β) for each compartment may be used to provide objective feedback during arthroscopic skills training. ...