A. R. Wu
Please Note
2 records found
1
Symbitron Exoskeleton
Design, control, and evaluation of a modular exoskeleton for incomplete and complete spinal cord injured individuals
In this paper, we present the design, control, and preliminary evaluation of the Symbitron exoskeleton, a lower limb modular exoskeleton developed for people with a spinal cord injury. The mechanical and electrical configuration and the controller can be personalized to accommodate differences in impairments among individuals with spinal cord injuries (SCI). In hardware, this personalization is accomplished by a modular approach that allows the reconfiguration of a lower-limb exoskeleton with ultimately eight powered series actuated (SEA) joints and high fidelity torque control. For SCI individuals with an incomplete lesion and sufficient hip control, we applied a trajectory-free neuromuscular control (NMC) strategy and used the exoskeleton in the ankle-knee configuration. For complete SCI individuals, we used a combination of a NMC and an impedance based trajectory tracking strategy with the exoskeleton in the ankle-knee-hip configuration. Results of a preliminary evaluation of the developed hardware and software showed that SCI individuals with an incomplete lesion could naturally vary their walking speed and step length and walked faster compared to walking without the device. SCI individuals with a complete lesion, who could not walk without support, were able to walk with the device and with the support of crutches that included a push-button for step initiationOur results demonstrate that an exoskeleton with modular hardware and control allows SCI individuals with limited or no lower limb function to receive tailored support and regain mobility.
This work was devoted to preliminary test the Achilles ankle exoskeleton and its NeuroMuscular Controller (NMC) with a test pilot affected by incomplete spinal cord injury. The customization of the robot controller, i.e. a subject-specific tailoring of the assistance level, was performed and a 10-session training to optimize human-robot interaction was finalized. Results demonstrated that controller tuning was in line with the functional clinical assessment. NMC adapted to the variable walking speed during the training and the test pilot was successfully trained in exploiting robotic support and also improved his performance in terms of walking speed and stability. After the training, a higher speed could also be achieved during free walking and hence a slight unexpected rehabilitation effect was evidenced.