JJ

J Jeekel

info

Please Note

2 records found

Journal article (2017) - KA Vakalopoulos, Z Wu, L.F. Kroese, J Jeekel, GJ Kleinrensink, Dimitra Dodou, K.H. Lam, J.F. Lange
Background Tissue adhesives (TAs) in gastrointestinal surgery are gradually gaining acceptance. Before implementation as colonic sealants, an evaluation of the sealing capability of a TA when in contact with fecal matter, as in a leaking anastomosis, is needed. In this study, we used clinically available TAs for the sutureless closure of colonic defects evaluating mechanical strength and tissue healing. Methods A total of 160 rats were divided into 8 groups. Two .5-cm incisions were created, one in the proximal and another in the distal colon. Incisions were sealed with a TA: Histoacryl Flex, Bioglue, Dermabond, Tissucol, Duraseal Xact, gelatin-resorcinol-formaldehyde or Glubran 2. A control group was included in which the colonic defects were not sealed. Follow-up time was 3 or 10 days. Clinical complication rate, bursting pressure, and histopathologic analysis was included. Results Leakage rates in the TA groups were highest for Duraseal Xact, Bioglue, and gelatin-resorcinol-formaldehyde at 3 and 10 days. The cyanoacrylates Glubran 2, Histoacryl Flex, and Omnex, and the fibrin glue Tissucol showed the lowest overall clinical complication rates while maintaining the highest bursting pressure at day 10. Histoacryl Flex exhibited significantly higher collagen formation at day 10 than the other TAs. Conclusions This experimental model evaluates the protective effect of a TA seal on a leaking colonic defect. We found large differences in leakage rates and inertness of the tested TAs. The cyanoacrylates Histoacryl Flex, Omnex, and Glubran 2 as well as the fibrin glue Tissucol demonstrated the lowest leakage rates and the most inert histopathologic profile while maintaining high mechanical strength. ...

An artificial abdominal wall simulator for biomechanical studies on laparotomy closure techniques

Journal article (2017) - Leonard F. Kroese, Joris J. Harlaar, C. Ordrenneau, JM Verhelst, G. Guérin, F. Turquier, Richard Goossens, GJ Kleinrensink, J Jeekel, Johan F. Lange
Purpose: Incisional hernia remains a frequent complication after abdominal surgery associated with significant morbidity and high costs. Animal and clinical studies have exhibited some limitations. The purpose of this study was to develop an artificial human abdominal wall (AW) simulator in order to enable investigations on closure modalities. We hypothesized that a physical model of the human AW would give new insight into commonly used suture techniques representing a substantial complement or alternative to clinical and animal studies. Methods: The ‘AbdoMAN’ was developed to simulate human AW biomechanics. The ‘AbdoMAN’ capacities include measurement and regulation of intra-abdominal pressure (IAP), generation of IAP peaks as a result of muscle contraction and measurements of AW strain patterns analyzed with 3D image stereo correlation software. Intact synthetic samples were used to test repeatability. A laparotomy closure was then performed on five samples to analyze strain patterns. Results: The ‘AbdoMAN’ was capable of simulating physiological conditions. AbdoMAN lateral muscles contract at 660 N, leading the IAP to increase up to 74.9 mmHg (range 65.3–88.3). Two strain criteria were used to assess test repeatability. A test with laparotomy closure demonstrated closure testing repeatability. Conclusions: The ‘AbdoMAN’ reveals as a promising enabling tool for investigating AW surgery-related biomechanics and could become an alternative to animal and clinical studies. 3D image correlation analysis should bring new insights on laparotomy closure research. The next step will consist in evaluating different closure modalities on synthetic, porcine and human AW. ...