document
-
Quintavalla, M. (author), Pozzi, P. (author), Verhaegen, M.H.G. (author), Bijlsma, H.K. (author), Verstraete, H.R.G.W. (author), Bonora, S. (author)
Adaptive Optics (AO) has revealed as a very promising technique for high-resolution microscopy, where the presence of optical aberrations can easily compromise the image quality. Typical AO systems however, are almost impossible to implement on commercial microscopes. We propose a simple approach by using a Multi-actuator Adaptive Lens (MAL)...
conference paper 2018
-
document
-
Pozzi, P. (author), Quintavalla, M. (author), Verstraete, H.R.G.W. (author), Bijlsma, Hielke (author), Bonora, S. (author), Verhaegen, M.H.G. (author) conference paper 2017
-
document
-
Mocci, J. (author), Cua, M. (author), Lee, S. (author), Jian, Y (author), Pozzi, P. (author), Quintavalla, M. (author), Trestino, C. (author), Verstraete, H.R.G.W. (author), Wahl, D. (author), Muradore, R. (author), Zawadzki, R.J. (author), Verhaegen, M.H.G. (author), Sarunic, M.V. (author), Bonora, S. (author)
The use of adaptive lenses instead of deformable mirrors can simplify the implementation of an adaptive optics system. The recently introduced Multi-actuator Adaptive Lens (MAL) can be used in closed loop with a wavefront sensor to correct for time-variant wavefront aberrations. The MAL can guarantee a level of correction and a response time...
conference paper 2017
-
document
-
Verstraete, H.R.G.W. (author), Almasian, M. (author), Pozzi, P. (author), Bilderbeek, R (author), Kalkman, J. (author), Faber, DJ (author), Verhaegen, M.H.G. (author)
In this manuscript, we present a lens setup for large defocus and astigmatism correction. A deformable defocus lens and two rotational cylindrical lenses are used to control the defocus and astigmatism. The setup is calibrated using a simple model that allows the calculation of the lens inputs so that a desired defocus and astigmatism are...
conference paper 2016
-
document
-
Verstraete, H.R.G.W. (author), Verhaegen, M.H.G. (author), Kalkman, J. (author)
In scanning microscopy and optical coherence tomography, aberrations of the wave-front cause a loss in intensity and resolution. Intensity and resolution are quantified using Fresnel propagation, Fraunhofer diffraction, and the calculation of overlap integrals.
conference paper 2013