Efficient Leak Localization in Water Distribution Systems Using Multistage Optimal Valve Operations and Smart Demand Metering

Journal Article (2020)
Author(s)

Yuan Huang (Zhejiang University)

Feifei Zheng (Zhejiang University)

Zoran Kapelan (TU Delft - Sanitary Engineering)

Dragan Savic (KWR Water Research Institute, University of Exeter)

Huan Feng Duan (The Hong Kong Polytechnic University)

Research Group
Sanitary Engineering
Copyright
© 2020 Yuan Huang, Feifei Zheng, Z. Kapelan, Dragan Savić, Huan-Feng Duan
DOI related publication
https://doi.org/10.1029/2020WR028285
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 Yuan Huang, Feifei Zheng, Z. Kapelan, Dragan Savić, Huan-Feng Duan
Research Group
Sanitary Engineering
Issue number
10
Volume number
56
Pages (from-to)
1-21
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This paper proposes a multistage method for burst leak localization through valve operations (VOs) and smart demand metering in district meter areas (DMAs) of water distribution systems (WDSs). Each stage includes partitioning of the DMA into two subregions using VOs and identification of potentially leaking pipes within the subregions through water balance analysis based on smart demand meters. Such a process is performed repeatedly (multiple stages) to narrow down the spatial range for pinpointing leak locations. To improve efficiency, a bisection optimization problem is formulated to localize the minimum leak areas using the lowest number of VOs, which is solved by a graph theory-based method. The utility of the proposed method is demonstrated using two DMAs (DMA1 and DMA2) of a real WDS with different topological properties. Results show that the proposed method can efficiently localize artificial burst leaks in DMA1 within 7–15% of the total pipe length, implying that the proposed method is theoretically effective in localizing pipe burst leaks. The real application to DMA2 has identified two leak regions with 2.3 and 4.2 km of pipe length (around 3–6% of the entire DMA2) using 18 VOs. These two burst leaks have been subsequently confirmed and pinpointed using listening rods by practitioners of the local water utility. These results indicate that the proposed multistage method is effective and efficient for burst leak localization, which can be promising for wide practical applications due to rapid developments of smart WDSs (e.g., smart demand meters or control valves).

Files

2020WR028285.pdf
(pdf | 4.63 Mb)
- Embargo expired in 06-04-2021
License info not available