Noncontact monitoring of respiratory rate in newborn infants using thermal imaging

Journal Article (2019)
Author(s)

Carina Barbosa Pereira (RWTH Aachen University)

Xinchi Yu (RWTH Aachen University)

Tom Goos (Erasmus MC, TU Delft - Medical Instruments & Bio-Inspired Technology)

Irwin Reiss (Erasmus MC)

Thorsten Orlikowsky (RWTH Aachen University)

Konrad Heimann (RWTH Aachen University)

Boudewijn Venema (RWTH Aachen University)

Vladimir Blazek (RWTH Aachen University, Czech Technical University)

Steffen Leonhardt (RWTH Aachen University)

Daniel Teichmann (RWTH Aachen University)

Research Group
Medical Instruments & Bio-Inspired Technology
DOI related publication
https://doi.org/10.1109/TBME.2018.2866878
More Info
expand_more
Publication Year
2019
Language
English
Research Group
Medical Instruments & Bio-Inspired Technology
Issue number
4
Volume number
66
Pages (from-to)
1105-1114

Abstract

Monitoring of respiratory rate (RR) is very important for patient assessment. In fact, it is considered one of the relevant vital parameters in critical care medicine. Nowadays, standard monitoring relies on obtrusive and invasive techniques, which require adhesive electrodes or sensors to be attached to the patient's body. Unfortunately, these procedures cause stress, pain, and frequently damage the vulnerable skin of preterm infants. This paper presents a 'black-box' algorithm for remote monitoring of RR in thermal videos. 'Black-box' in this context means that the algorithm does not rely on tracking of specific anatomic landmarks. Instead, it automatically distinguishes regions of interest in the video containing the respiratory signal from those containing only noise. To examine its performance and robustness during physiological (phase A) and pathological scenarios (phase B), a study on 12 healthy volunteers was carried out. After a successful validation on adults, a clinical study on eight newborn infants was conducted. A good agreement between estimated RR and ground truth was achieved. In the study involving adult volunteers, a mean root-mean-square error (RMSE) of (0.31 ± 0.09) breaths/min and (3.27 ± 0.72) breaths/min was obtained for phase A and phase B, respectively. In the study involving infants, the mean RMSE hovered around (4.15 ± 1.44) breaths/min. In brief, this paper demonstrates that infrared thermography might become a clinically relevant alternative for the currently available RR monitoring modalities in neonatal care.