3D Numerical Analysis of Installation Effects of Displacement Piles in Dikes

Conference Paper (2026)
Author(s)

Majd Ahmad (TU Delft - Civil Engineering & Geosciences)

Ronald B.J. Brinkgreve (TU Delft - Civil Engineering & Geosciences)

Bas S.N. Jonkman (TU Delft - Civil Engineering & Geosciences)

Research Group
Hydraulic Structures and Flood Risk
DOI related publication
https://doi.org/10.11159/icgre26.131 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Research Group
Hydraulic Structures and Flood Risk
Article number
ICGRE 131
Publisher
Avestia Publishing
ISBN (print)
9781990800528
Event
11th World Congress on Civil, Structural, and Environmental Engineering, CSEE 2026 (2026-04-16 - 2026-04-18), Paris, France
Page Views
82
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This study investigates the installation effects of displacement piles used as a dike reinforcement method through advanced finite element modelling in PLAXIS 3D. The analysis builds on a previously developed PLAXIS 2D model, which used an equivalent diameter approach to approximate the pile wall effect. While 2D plane strain models offer computational efficiency and generally conservative estimates, they cannot fully capture three-dimensional effects such as out-of-plane deformations, spatial stress redistribution, and pile group interactions. A detailed 3D model was developed using the same geometry and soil parameters as the 2D model, based on the Bergambacht dike case. A volumetric strain method was employed to simulate the soil displacement caused by pile installation. The results indicate that the 3D model predicts displacements comparable to those of the 2D model at the toe of the dike. Beyond this point towards the polder side, the displacements gradually decrease, reaching values up to 20% lower than the 2D model within the first 12 meters, after which the results converge. The study concludes that the 2D equivalent diameter approach is considered a conservative approach and is suitable for preliminary design and assessment when buildings are located more than five meters from the dike toe. For closer structures or more refined evaluations, 3D modelling is recommended. The findings underline the importance of calibrating structural responses, particularly for embedded beam elements, using pile load test data to ensure reliable results.

Files

ICGRE_131.pdf
(pdf | 0.941 Mb)
- Embargo expired in 18-10-2026
– Personal use only – Dutch Copyright Act (Article 25fa)