Structural Integrity Analyses of Inline Structures in the Overbend Section

Master Thesis (2026)
Author(s)

I.L. Gonzalo (TU Delft - Mechanical Engineering)

Contributor(s)

W. van den Bos – Mentor (TU Delft - Mechanical Engineering)

J. Jovanova – Graduation committee member (TU Delft - Mechanical Engineering)

Faculty
Mechanical Engineering
More Info
expand_more
Publication Year
2026
Language
English
Graduation Date
06-05-2026
Awarding Institution
Delft University of Technology
Project
ME54035
Programme
Mechanical Engineering, Multi-Machine Engineering
Faculty
Mechanical Engineering
Page Views
90
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This research project investigates pipeline installation analyses using non-linear finite element models and multi-body models. Non-linear finite element models allow for high-fidelity modelling and are therefore mostly used for localized analyses. Multi-body models enable complete modelling of installation scenarios, where the global behaviour of the pipeline can be analysed. Multi-body analyses are the standard procedure for pipeline installation analyses due to their significantly low runtime when capturing global behaviour.

Non-linear finite element models provide high fidelity and are therefore considered realistic. While they can also be used to analyse global behaviour, they are primarily used to benchmark multi-body models, as global analyses with such models have significantly high runtimes due to their fidelity. Multi-body models, by contrast, have an overall lower fidelity, allowing for shorter runtimes while still modelling the complete scenario and capturing pipeline behaviour. For homogeneous pipelines, multi-body models can closely approximate behaviour. However, when an inline structure is included within the pipeline, questions arise regarding modelling viability and result fidelity.

This research project aims to analyse current pipeline installation analysis methods by assessing both multi-body models and non-linear finite element models, as well as their respective roles in homogeneous pipeline and inline structure analyses. An inline structure from a past project is used to benchmark results from both modelling approaches. An alternative, time-efficient inline structure modelling method is also investigated and benchmarked.

Both modelling setups are compared to gain further insight into their similarities and differences. Additionally, possible pain points are identified, along with corresponding solutions and improvements. From this comparison, two improvements are directly implemented to minimize the modelling-difference gap. By reducing this gap, any remaining differences in results can be attributed to inherent systematic differences.

Since both modelling approaches can closely approximate the behaviour of a homogeneous pipeline, a pipeline is modelled in both software environments using similar setups, and their static analysis results are compared. By analysing an identical homogeneous pipeline, inherent systematic differences can be identified. Understanding these differences beforehand allows for more informed comparisons when analysing inline structures.

This research project concludes that, for homogeneous pipeline installation analyses, multi-body models closely approximate the results of non-linear finite element models. For pipelines with inline structures, discrepancies arise: multi-body models slightly overestimate results, though this is considered a conservative design approach. The alternative time-efficient modelling method results in two simplified inline structures, each with a different material definition. Both deliver similar results despite their lower fidelity compared to the original multi-body inline structure model.

In cases where time is critical and rapid analyses are required, simplifying the inline structure in this manner provides conservative results that remain close to reality. Meeting established design criteria with this simplified model indicates that the design is structurally sound and viable for installation. When time constraints are less critical, it is recommended to improve fidelity in OrcaFlex by increasing the number of sections used—more than the three applied in this research. Higher fidelity reduces design conservatism and limits over-engineering, thereby lowering overall production costs.

Files

License info not available