Validating MRI-Derived Myocardial Stiffness Estimates Using In Vitro Synthetic Heart Models

Journal Article (2023)
Author(s)

Fikunwa O. Kolawole (Stanford University, VA Palo Alto Health Care System)

M. Peirlinck (TU Delft - Medical Instruments & Bio-Inspired Technology)

Tyler E. Cork (VA Palo Alto Health Care System, Stanford University)

Marc Levenston (Stanford University)

E. Kuhl (Stanford University)

Daniel B. Ennis (VA Palo Alto Health Care System, Stanford University School of Medicine)

Research Group
Medical Instruments & Bio-Inspired Technology
Copyright
© 2023 F. O. Kolawole, M. Peirlinck, T. E. Cork, M. Levenston, Ellen Kuhl, D. B. Ennis
DOI related publication
https://doi.org/10.1007/s10439-023-03164-7
More Info
expand_more
Publication Year
2023
Language
English
Copyright
© 2023 F. O. Kolawole, M. Peirlinck, T. E. Cork, M. Levenston, Ellen Kuhl, D. B. Ennis
Research Group
Medical Instruments & Bio-Inspired Technology
Issue number
7
Volume number
51
Pages (from-to)
1574-1587
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Impaired cardiac filling in response to increased passive myocardial stiffness contributes to the pathophysiology of heart failure. By leveraging cardiac MRI data and ventricular pressure measurements, we can estimate in vivo passive myocardial stiffness using personalized inverse finite element models. While it is well-known that this approach is subject to uncertainties, only few studies quantify the accuracy of these stiffness estimates. This lack of validation is, at least in part, due to the absence of ground truth in vivo passive myocardial stiffness values. Here, using 3D printing, we created soft, homogenous, isotropic, hyperelastic heart phantoms of varying geometry and stiffness and simulate diastolic filling by incorporating the phantoms into an MRI-compatible left ventricular inflation system. We estimate phantom stiffness from MRI and pressure data using inverse finite element analyses based on a Neo-Hookean model. We demonstrate that our identified softest and stiffest values of 215.7 and 512.3 kPa agree well with the ground truth of 226.2 and 526.4 kPa. Overall, our estimated stiffnesses revealed a good agreement with the ground truth (< 5.8 % error) across all models. Our results suggest that MRI-driven computational constitutive modeling can accurately estimate synthetic heart material stiffnesses in the range of 200–500 kPa.

Files

S10439_023_03164_7.pdf
(pdf | 6.4 Mb)
- Embargo expired in 13-09-2023
License info not available