Quicker measurement of walls' thermal resistance following an extension to ISO 9869 average method

Journal Article (2019)
Author(s)

Arash Rasooli (TU Delft - Building Energy Epidemiology)

Laure Itard (TU Delft - Building Energy Epidemiology)

Research Group
Building Energy Epidemiology
DOI related publication
https://doi.org/10.1051/e3sconf/201911104019 Final published version
More Info
expand_more
Publication Year
2019
Language
English
Research Group
Building Energy Epidemiology
Volume number
111
Article number
04019
Event
CLIMA 2019: REHVA 13th HVAC World Congress (2019-05-26 - 2019-05-29), Bucharest, Romania
Downloads counter
213
Collections
Institutional Repository
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Determination of the thermo-physical characteristics of the buildings' components is crucial to illustrate their thermal behavior and therefore their energy consumption. Along the same line, accurate determination of the thermal resistance of the building walls falls into one the most important targets. Following the difference between in-lab, and on site thermal performance of walls, in-situ measurements have been highly recommended. The most well-known practice for in-situ measurement of walls' thermal resistance is the Average Method of ISO 9869, using one heat flux meter and two thermocouples. The method, in comparison with other existing methods is quite straight-forward and therefore, is applied widely in large scale. Despite its simplicity, this method usually needs a relatively long time to reach an acceptable result. The current paper deals with a modification to the ISO 9869 method, making it in many situations much quicker than its original state. Through simulation of walls of different typologies, it is shown in which cases the measurement period becomes longer than expected. It is demonstrated how the addition of a heat flux meter to the aforementioned equipment can lead to a much quicker achievement of the thermal resistance, following the rest of the instructions of the standard method.