Using a sacral cluster to improve pelvic tracking during gait in overweight individuals
N. B.J. Dur (Erasmus MC)
L. M.S. Damink (Erasmus MC, Student TU Delft)
E. M. Macri (Erasmus MC)
M. G.H. Wesseling (TU Delft - Mechanical Engineering, Erasmus MC)
R. A. Van der Heijden (Erasmus MC)
E. H.G. Oei (Erasmus MC)
J. Harlaar (TU Delft - Mechanical Engineering, Erasmus MC)
W. Schallig (Erasmus MC)
More Info
expand_more
Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.
Abstract
Background: Pelvic tracking in three-dimensional (3D) human motion analysis commonly uses skin-mounted anterior superior iliac spines (ASIS) markers. However, these conventional methods are prone to soft tissue artifacts, especially in overweight individuals. Using a sacral marker cluster with pointer-defined virtual ASIS markers might be an alternative approach for more accurate pelvic tracking across different body compositions. Research Question: What are the differences in pelvic and hip joint mechanics measured during gait using conventional pelvic tracking versus pelvic tracking with a sacral cluster in healthy-weight and overweight individuals? Methods: Ten healthy-weight and ten overweight/obese participants underwent 3D gait analysis. The pelvis was simultaneously tracked using skin-mounted markers and a sacral cluster with pointer-defined virtual ASIS markers. Pelvic kinematics and hip kinematics and kinetics were compared between tracking methods using statistical parametric mapping paired t-tests. Root mean squared differences (RMSD) and paired Cohen's dz were calculated for significantly different waveform regions. Results: Frontal-plane pelvic kinematics differed between methods more substantially in the overweight group (RMSD=4.6° ± 1.7°, dz=-0.9) than in the healthy-weight group (RMSD=2.8° ± 0.8°, dz=0.3). Frontal-plane hip kinematics also differed more substantially in the overweight group (RMSD=5.4° ± 2.3°, dz=-0.8) than in the healthy-weight group (RMSD=2.7° ± 1.7°, dz=1.4). Hip kinetics differed mostly in the sagittal plane, with more substantial differences in the overweight group (RMSD=0.22 ± 0.09Nm/kg, dz=2.3) than in the healthy-weight group (RMSD=0.11 ± 0.04Nm/kg, dz=2.7). Discussion: Pelvic tracking using a sacral cluster with pointer-defined virtual ASIS markers provides different, and potentially more accurate, pelvic and hip mechanics across different body compositions than conventional methods using skin-mounted ASIS markers.