Start-up of non-bioaugmented pumice biofilters in flow-through and recirculating flow regime for Mn removal

Journal Article (2023)
Author(s)

José Andrés Araya-Obando (Instituto Tecnologico de Costa Rica)

L.C. Rietveld (TU Delft - Sanitary Engineering)

Daniel E. Kelly-Coto (Instituto Tecnologico de Costa Rica)

Andrea Quesada-González (Instituto Tecnologico de Costa Rica)

Andrey Caballero-Chavarría (Instituto Tecnologico de Costa Rica)

Luis G. Romero-Esquivel (Instituto Tecnologico de Costa Rica)

Research Group
Sanitary Engineering
Copyright
© 2023 José Andrés Araya-Obando, L.C. Rietveld, Daniel E. Kelly-Coto, Andrea Quesada-González, Andrey Caballero-Chavarría, Luis G. Romero-Esquivel
DOI related publication
https://doi.org/10.2166/WS.2023.045
More Info
expand_more
Publication Year
2023
Language
English
Copyright
© 2023 José Andrés Araya-Obando, L.C. Rietveld, Daniel E. Kelly-Coto, Andrea Quesada-González, Andrey Caballero-Chavarría, Luis G. Romero-Esquivel
Research Group
Sanitary Engineering
Issue number
4
Volume number
23
Pages (from-to)
1587-1598
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Biofilters are effectively used for drinking water treatment. However, the long ripening time of virgin media for manganese (Mn) removal is a major concern. In this study, the influence of the flow regime on the ripening time of virgin pumice medium was investigated. For this purpose, pilot-scale experiments were performed to compare the start-up of flow-through and recirculating filter columns using inherent inoculation with the same groundwater source. The systems were operated at 2 m·h1 with gradual flow increments up to 5 m·h1 and avoiding Fe-loading. Effective Mn removal (.90%) in flow-through and recirculating columns was achieved after 8 and 23 days, respectively. Flow-through columns reached compliance with a local drinking water criterion (Mn, 0.1 mg·L1) at 15 cm filter depth in 11 days. Recirculating filter columns required 32 days to reach compliance at 30 cm depth. The start-up in recirculation regime resulted in a water consumption reduction of about 50% compared with flow-through regime. The intermittent provision of the Mn-loading in recirculating regime impacted the Mn-oxidizing bacteria (MOB) concentration in the pumice stone medium. Both flow regimes required a similar total Mn-loading (0.16 and 0.11 kg·Mn·m2, respectively), suggesting that Mn-loading was the limiting factor for the ripening of pumice.