Spatially resolved gas fraction measurements in a bubble column through three-angled X-ray tomography

Journal Article (2026)
Author(s)

Rik Volger (TU Delft - Applied Sciences)

Sam J. den Hartog (Student TU Delft)

Evert C. Wagner (TU Delft - Applied Sciences)

Cees Haringa (TU Delft - Applied Sciences)

Research Group
BT/Bioprocess Engineering
DOI related publication
https://doi.org/10.1016/j.ijmultiphaseflow.2026.105873 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Related content
Research Group
BT/Bioprocess Engineering
Journal title
International Journal of Multiphase Flow
Volume number
203
Article number
105873
Page Views
51
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Bubble columns are a popular choice for large-scale bioprocesses, yet model-based performance predictions provide major uncertainties in scale-up. High-resolution experimental data on local gas fraction and bubble size distribution are essential for reducing these uncertainties. Unfortunately, experimental characterization of gas-phase dynamics is often challenging. This study investigates a 3-angled X-ray tomography setup for measurement of spatially resolved gas fraction profiles in a 20 cm internal diameter bubble column with 100 cm static liquid height. X-ray scatter and beam hardening are identified as main sources of measurement error, and corrections were proposed and tested. It was found that software-based post-processing image corrections could correct for the effects of both beam hardening and cross-scatter resulting in gas fraction profiles that closely matched literature data for superficial gas velocity (ug,s) of 1.7 cm s-1, 4.6 cm s-1, 5.8 cm s-1 and 8.6 cm s-1. Comparison between X-ray tomography and radial profiles from optical fiber probe and pressure probe measurements showed a discrepancy, with the fiber probe and pressure probes reporting roughly 20 % lower gas fraction values. An extra correction term might be needed to bring X-ray tomography into quantitative agreement with the complementary measurement methods. Overall, our work shows that three-angled X-ray tomography allows for rapid and reliable acquisition of gas fraction profiles in scale-invariant bubble columns. The method is a factor twelve faster than optical fiber probes, with increased radial resolution, but lacking the spatial and temporal resolution to identify single bubbles. The combination of X-ray tomography for gas fraction and fiber probes for bubble size distribution is an attractive setup for systematic studies gas phase dynamics in bubble columns.