Quantifying defects in ceramic tight ultra- and nanofiltration membranes and investigating their robustness

Journal Article (2019)
Author(s)

FC Kramer (TU Delft - Sanitary Engineering)

Ran Shang (TU Delft - Sanitary Engineering)

S. M. Scherrenberg (Evides N.V.)

Luuk C. Rietveld (TU Delft - Sanitary Engineering)

Sebastiaan Heijman (TU Delft - Sanitary Engineering)

Research Group
Sanitary Engineering
Copyright
© 2019 F.C. Kramer, R. Shang, S. M. Scherrenberg, L.C. Rietveld, Sebastiaan Heijman
DOI related publication
https://doi.org/10.1016/j.seppur.2019.03.019
More Info
expand_more
Publication Year
2019
Language
English
Copyright
© 2019 F.C. Kramer, R. Shang, S. M. Scherrenberg, L.C. Rietveld, Sebastiaan Heijman
Research Group
Sanitary Engineering
Volume number
219
Pages (from-to)
159-168
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

One of the perceived benefits of ceramic membranes is their robustness, which makes them suitable for treating high organic load waste streams. In particular, ceramic tight ultrafiltration (tUF) and nanofiltration (NF) form an important barrier against small colloids and organic molecules. In order to achieve this barrier, the quality of the membranes should be uncompromised. An extension on a commonly used size exclusion method was developed in order to quantify defects in membranes and calculate the MWCO accurately excluding the defects. This approach gives a better representation of the membrane quality than the original method. The quality of a broad range of commercial ceramic membranes was investigated by determining the (i) hydraulic permeability, (ii) molecular weight cut-off, and (iii) quantitative defects. Several membranes – both tubular and disc membranes, selected from various suppliers – were tested to investigate their variability. Furthermore, the robustness of tubular NF membranes was studied by monitoring the effect of long-term exposure to sodium hypochlorite, which is commonly used to mitigate organic fouling. The results showed that batches of both tubular and disc membranes of different pore size and suppliers included membranes with defects. Furthermore, the long-term treatment of tubular ceramic membranes with sodium hypochlorite negatively affected, beyond expectation, the quality of the membranes. The separation layer in these membranes was not notably compromised by sodium hypochlorite exposure, but the end seal layer was damaged.

Files

1_s2.0_S1383586618325759_main.... (pdf)
(pdf | 2.73 Mb)
- Embargo expired in 06-09-2019
License info not available