Techno-economic assessment and operational CO2 emissions of High-Temperature Aquifer Thermal Energy Storage (HT-ATES) using demand-driven and subsurface-constrained dimensioning

Journal Article (2022)
Author(s)

Alex Daniilidis (Université de Genève, TU Delft - Reservoir Engineering)

Julian E. Mindel (ETH Zürich)

Fleury De Oliveira Filho (Université de Genève)

L. Guglielmetti (Université de Genève)

Research Group
Reservoir Engineering
Copyright
© 2022 Alexandros Daniilidis, Julian E. Mindel, Fleury De Oliveira Filho, Luca Guglielmetti
DOI related publication
https://doi.org/10.1016/j.energy.2022.123682
More Info
expand_more
Publication Year
2022
Language
English
Copyright
© 2022 Alexandros Daniilidis, Julian E. Mindel, Fleury De Oliveira Filho, Luca Guglielmetti
Research Group
Reservoir Engineering
Volume number
249
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

High-Temperature – Aquifer Thermal Energy Storage (HT-ATES) can significantly increase Renewable Energy Sources (RES) capacity and storage temperature levels compared to traditional ATES, while improving efficiency. Combined assessment of subsurface performance and surface District Heating Networks (DHN) is key, but poses challenges for dimensioning, energy flow matching, and techno-economic performance of the joint system. We present a novel methodology for dimensioning and techno-economic assessment of an HT-ATES system combining subsurface, DHN, operational CO 2 emissions, and economics. Subsurface thermo-hydraulic simulations consider aquifer properties (thickness, permeability, porosity, depth, dip, artesian conditions and groundwater hydraulic gradient) and operational parameters (well pattern and cut-off temperature). Subject to subsurface constraints, aquifer permeability and thickness are major control variables. Transmissivity ≥2.5 × 10 −12 m3 is required to keep the Levelised Cost Of Heat (LCOH) below 200 CHF/MWh and capacity ≥25 MW is needed for the HT-ATES system to compete with other large-scale DHN heat sources. Addition of Heat Pumps (HP) increases the LCOH, but also the nominal capacity of the system and yields higher cumulative avoided CO 2 emissions. The methodology presented exemplifies HT-ATES dimensioning and connection to DHN for planning purposes and opens-up the possibility for their fully-coupled assessment in site-specific assessments.