Effects of water quality changes on performance of biological activated carbon (BAC) filtration

Journal Article (2019)
Author(s)

Petra Ross (TU Delft - Sanitary Engineering)

L. T.J. van der Aa (Waternet, TU Delft - Sanitary Engineering)

T. van Dijk (Brabant Water N.V.)

L. C. Rietveld (TU Delft - Sanitary Engineering)

Research Group
Sanitary Engineering
Copyright
© 2019 P.S. Ross, L.T.J. van der Aa, T. van Dijk, L.C. Rietveld
DOI related publication
https://doi.org/10.1016/j.seppur.2018.11.072
More Info
expand_more
Publication Year
2019
Language
English
Copyright
© 2019 P.S. Ross, L.T.J. van der Aa, T. van Dijk, L.C. Rietveld
Research Group
Sanitary Engineering
Volume number
212
Pages (from-to)
676-683
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Biological activated carbon (BAC) filtration is an important treatment step in the production of drinking water especially if drinking water is produced from surface water. The performance and processes within a BAC filter have been of interest for researchers since the 1980's, mainly because of its ability to remove natural organic matter known as disinfection precursors. A malfunction of one of the pre-treatment steps might affect the feed water quality into the BAC filters. The main objective of this study was to determine the immediate response of the BAC filters to a rapid change in feed water quality. It was shown that with the studied setup it was possible to compare the effect of different pre-treatment steps and subsequent different water qualities on the performance of the BAC filters on the long term adaptation. However, especially the immediate response was not studied in detail before. All filters were able to mitigate a sudden change in feed water quality, either through improved adsorption or increased activity of the biomass on the filter. As a result of this resilience against sudden changes, it is therefore concluded that there is no direct need for very stringent on-line monitoring and continuous adjustments of the feed water quality of the BAC filters. The addition of phosphate resulted in the lowest dissolved organic carbon (DOC) concentration in the effluent of the BAC filters. In this study the influence of intact cells in the feed water on the performance of the BAC filters was shown to be limited.

Files

1_s2.0_S1383586618324225_main.... (pdf)
(pdf | 0.978 Mb)