Patient-specific 3D-printed shelf implant for the treatment of hip dysplasia tested in an experimental animal pilot in canines

Journal Article (2022)
Author(s)

Koen Willemsen ( University Medical Centre Utrecht)

Marianna A. Tryfonidou (Universiteit Utrecht)

Ralph J.B. Sakkers ( University Medical Centre Utrecht)

René M. Castelein ( University Medical Centre Utrecht)

Martijn Beukers (Universiteit Utrecht)

Peter R. Seevinck ( University Medical Centre Utrecht)

Harrie Weinans ( University Medical Centre Utrecht, TU Delft - Biomaterials & Tissue Biomechanics)

Bart C.H. van der Wal ( University Medical Centre Utrecht)

Björn P. Meij (Universiteit Utrecht)

DOI related publication
https://doi.org/10.1038/s41598-022-06989-9 Final published version
More Info
expand_more
Publication Year
2022
Language
English
Journal title
Scientific Reports
Issue number
1
Volume number
12
Article number
3032
Downloads counter
312
Collections
Institutional Repository
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

The concept of a novel patient-specific 3D-printed shelf implant should be evaluated in a relevant large animal model with hip dysplasia. Therefore, three dogs with radiographic bilateral hip dysplasia and a positive subluxation test underwent unilateral acetabular augmentation with a 3D-printed dog-specific titanium implant. The contralateral side served as control. The implants were designed on CT-based pelvic bone segmentations and extended the dysplastic acetabular rim to increase the weight bearing surface without impairing the range of motion. Outcome was assessed by clinical observation, manual subluxation testing, radiography, CT, and gait analysis from 6 weeks preoperatively until termination at 26 weeks postoperatively. Thereafter, all hip joints underwent histopathological examination. The implantation and recovery from surgery was uneventful. Clinical subluxation tests at the intervention side became negative. Imaging showed medialization of the femoral head at the intervention side and the mean (range) CE-angle increased from 94° (84°-99°) preoperative to 119° (117°-120°) postoperative. Gait analysis parameters returned to pre-operative levels after an average follow-up of 6 weeks. Histology showed a thickened synovial capsule between the implant and the femoral head without any evidence of additional damage to the articular cartilage compared to the control side. The surgical implantation of the 3D shelf was safe and feasible. The patient-specific 3D-printed shelf implants restored the femoral head coverage and stability of dysplastic hips without complications. The presented approach holds promise to treat residual hip dysplasia justifying future veterinary clinical trials to establish clinical effectiveness in a larger cohort to prepare for translation to human clinic.