Safety assessment of hydro-generating units using experiments and grey-entropy correlation analysis

More Info
expand_more

Abstract

This paper focuses on the safety analysis of a nonlinear hydro-generating unit (HGU) running under different loads. For this purpose, a dynamic balance experiment implemented on an existing hydropower station in China is considered, to qualitatively investigate the stability of the system and to obtain the necessary indices for safety assessment. The experimental data are collected from four on-load units operating at different working heads including 431 m, 434 m, 437 m, and 440 m. A quantitative analysis on the safety performance of the four units was carried out by employing an integration of entropy weights method with grey correlation analysis. This assisted in obtaining the safety degree of each unit, providing the risk prompt to the operation of nonlinear hydro-generating units. The results confirm that unit 4 has the highest level of safety while unit 3 operates with the lowest safety condition. This provides the optimal operational schedule of HGUs to cope with the fluctuations of electricity demand in the studied station. The proposed methodology in this paper is not only applicable to the HGUs in the studied station but could also be adopted to assess the safety degree of any hydropower facility.

Files

1_s2.0_S0360544218318437_main.... (pdf)
(pdf | 2.18 Mb)
Unknown license

Download not available