Robust Local Thickness Estimation of Sub-Micrometer Specimen by 4D-STEM

Journal Article (2023)
Author(s)

Radim Skoupý (Kavli institute of nanoscience Delft, TU Delft - BN/Arjen Jakobi Lab, Czech Academy of Sciences)

D. B. Boltje (TU Delft - ImPhys/Hoogenboom group)

Miroslav Slouf (Czech Academy of Sciences)

Kateřina Mrázová (Czech Academy of Sciences)

Tomáš Láznička (Czech Academy of Sciences)

C.M. Taisne (TU Delft - BN/Arjen Jakobi Lab)

Vladislav Krzyžánek (Czech Academy of Sciences)

Jacob Hoogenboom (TU Delft - ImPhys/Hoogenboom group)

Arjen Jakobi (TU Delft - BN/Arjen Jakobi Lab)

Research Group
BN/Arjen Jakobi Lab
Copyright
© 2023 R. Skoupý, D.B. Boltje, Miroslav Slouf, Kateřina Mrázová, Tomáš Láznička, C.M. Taisne, Vladislav Krzyžánek, J.P. Hoogenboom, A. Jakobi
DOI related publication
https://doi.org/10.1002/smtd.202300258
More Info
expand_more
Publication Year
2023
Language
English
Copyright
© 2023 R. Skoupý, D.B. Boltje, Miroslav Slouf, Kateřina Mrázová, Tomáš Láznička, C.M. Taisne, Vladislav Krzyžánek, J.P. Hoogenboom, A. Jakobi
Research Group
BN/Arjen Jakobi Lab
Issue number
9
Volume number
7
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

A quantitative four-dimensional scanning transmission electron microscopy (4D-STEM) imaging technique (q4STEM) for local thickness estimation across amorphous specimen such as obtained by focused ion beam (FIB)-milling of lamellae for (cryo-)TEM analysis is presented. This study is based on measuring spatially resolved diffraction patterns to obtain the angular distribution of electron scattering, or the ratio of integrated virtual dark and bright field STEM signals, and their quantitative evaluation using Monte Carlo simulations. The method is independent of signal intensity calibrations and only requires knowledge of the detector geometry, which is invariant for a given instrument. This study demonstrates that the method yields robust thickness estimates for sub-micrometer amorphous specimen using both direct detection and light conversion 2D-STEM detectors in a coincident FIB-SEM and a conventional SEM. Due to its facile implementation and minimal dose reauirements, it is anticipated that this method will find applications for in situ thickness monitoring during lamella fabrication of beam-sensitive materials.