Minimizing tip-sample forces and enhancing sensitivity in atomic force microscopy with dynamically compliant cantilevers

Journal Article (2017)
Authors

Sasan Keyvani Janbahan (TNO, TU Delft - Computational Design and Mechanics)

H Sadeghian Marnani (TNO)

Selman Tamer (TU Delft - Computational Design and Mechanics, TNO)

Hans Goosen (TU Delft - Computational Design and Mechanics)

A van Keulen (TU Delft - Computational Design and Mechanics)

Research Group
Computational Design and Mechanics
Copyright
© 2017 A. Keyvani Janbahan, H. Sadeghian Marnani, M.S. Tamer, J.F.L. Goosen, A. van Keulen
To reference this document use:
https://doi.org/10.1063/1.4990276
More Info
expand_more
Publication Year
2017
Language
English
Copyright
© 2017 A. Keyvani Janbahan, H. Sadeghian Marnani, M.S. Tamer, J.F.L. Goosen, A. van Keulen
Research Group
Computational Design and Mechanics
Volume number
121
DOI:
https://doi.org/10.1063/1.4990276
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Due to the harmonic motion of the cantilever in Tapping Mode Atomic Force Microscopy, it is seemingly impossible to estimate the tip-sample interactions from the motion of the cantilever. Not directly observing the interaction force, it is possible to damage the surface or the tip by applying an excessive mechanical load. The tip-sample interactions scale with the effective stiffness of the
probe. Thus, the reduction of the mechanical load is usually limited by the manufacturability of low stiffness probes. However, the one-to-one relationship between spring constant and applied force only holds when higher modes of the cantilever are not excited. In this paper, it is shown that, by passively tuning higher modes of the cantilever, it is possible to reduce the peak repulsive force.
These tuned probes can be dynamically more compliant than conventional probes with the same static spring constant. Both theoretical and experimental results show that a proper tuning of dynamic modes of cantilevers reduces the contact load and increases the sensitivity considerably.
Moreover, due to the contribution of higher modes, the tuned cantilevers provide more information on the tip-sample interaction. This extra information from the higher harmonics can be used for mapping and possibly identification of material properties of samples.