A comparative evaluation of the sustainability of alternative aeration strategies in biological wastewater treatment to support net-zero future

Journal Article (2022)
Author(s)

David Pryce (University of Exeter)

Z. Kapelan (TU Delft - Sanitary Engineering, University of Exeter)

Fayyaz Ali Memon (University of Exeter)

Research Group
Sanitary Engineering
Copyright
© 2022 David Pryce, Z. Kapelan, Fayyaz A. Memon
DOI related publication
https://doi.org/10.1016/j.jclepro.2022.134005
More Info
expand_more
Publication Year
2022
Language
English
Copyright
© 2022 David Pryce, Z. Kapelan, Fayyaz A. Memon
Research Group
Sanitary Engineering
Volume number
374
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

In the plight for sustainable development and to support net zero ambitions for climate change mitigation, a broad range of aeration strategies have been developed with the hope of improving efficiency to minimize environmental and economic costs associated with the wastewater treatment processes. However, a balance is levied between reducing oxygen availability and hindering aerobic processes thus compromising performance. In the present work, we evaluate and compare the sustainability of a range of investigated strategies including continuous aeration (CA) at different dissolved oxygen (DO) setpoints (0.5 mg/L, 2.5 mg/L, 4.5 mg/L) and intermittent aeration (IA) at different oxic-anoxic portions (2.5 h on/0.5 h off, 2.0 h on/1.0 h off, 1.5 h on/1.0 h off). To achieve this, an eco-efficiency assessment is performed based on the results of previous life cycle impact and costing analyses for each strategy, while also incorporating a third factor to account for their respective treatment performance. The results demonstrate a clear pattern of increased sustainability for the IA strategies (0.54–0.56 Pt/m3), compared to the CA strategies (0.76–0.77 Pt/m3). While only negligible difference was observed within each aeration type, the trade-off between environmental and economic efficiency and treatment performance was distinct in CA strategies. At the individual pollutant level, IA strategies demonstrated decreasing sustainability for total phosphorous (TP) removal as the anoxic cycle portion increased, while CA at 0.5 mg/L was shown to be the most sustainable strategy for the removal of this pollutant (0.61 Pt/m3). Further work is suggested to incorporate the relative N2O emissions generated by each strategy and to investigate other strategies based on automated control.