Development of a Ti/Au TES Microcalorimeter Array as a Backup Sensor for the Athena/X-IFU Instrument

Journal Article (2019)
Author(s)

Kenichiro Nagayoshi (SRON–Netherlands Institute for Space Research)

M. L. Ridder (SRON–Netherlands Institute for Space Research)

M.P. de Bruijn (SRON–Netherlands Institute for Space Research)

L. Gottardi (SRON–Netherlands Institute for Space Research)

E. Taralli (SRON–Netherlands Institute for Space Research)

P Khosropanah (SRON–Netherlands Institute for Space Research)

H. Akamatsu (SRON–Netherlands Institute for Space Research)

S. Visser (SRON–Netherlands Institute for Space Research)

J.R. Gao (Kavli institute of nanoscience Delft, TU Delft - QN/Gao Lab, SRON–Netherlands Institute for Space Research)

Research Group
QN/Gao Lab
Copyright
© 2019 K. Nagayoshi, M. L. Ridder, M. P. Bruijn, L. Gottardi, E. Taralli, P. Khosropanah, H. Akamatsu, S. Visser, J.R. Gao
DOI related publication
https://doi.org/10.1007/s10909-019-02282-8
More Info
expand_more
Publication Year
2019
Language
English
Copyright
© 2019 K. Nagayoshi, M. L. Ridder, M. P. Bruijn, L. Gottardi, E. Taralli, P. Khosropanah, H. Akamatsu, S. Visser, J.R. Gao
Research Group
QN/Gao Lab
Issue number
3-4
Volume number
199
Pages (from-to)
943-948
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

We are developing a transition edge sensor (TES) microcalorimeter array based on a Ti/Au superconducting bilayer, as a backup option for the X-IFU instrument on the Athena X-ray observatory. The array is read out by a frequency-division multiplexing readout system using a 1–5 MHz frequency band. Extensive research collaborations between NASA/Goddard and SRON have led to new design rules for microcalorimeters such as low resistivity of the superconductor bilayer, moderately high ohmic resistance of the TES by changing the aspect ratio and no extra metal strips. We have improved our detector fabrication process according to these design principles and produced TES arrays. Although single-pixel characterizations of these arrays are ongoing, the best energy resolution of 2.0 eV for 5.9 keV X-ray has been observed with a 120 × 20 μm2 TES with a normal resistance of 150 mΩ, biased at 2.2 MHz frequency. This shows that our Ti/Au TES array has a potential to fulfill the detector requirements of the X-IFU instrument.