Measured data from sensor Q1 at Maisbich for month 2007-02

Other (2011)
Author(s)

W.M.J. Luxemburg (TU Delft - Water Resources)

CA van den Dool (TU Delft - Water Resources)

EH Durr (External organisation)

Research Group
Water Resources
DOI 4TU.ResearchData dataset
https://doi.org/10.4121/uuid:2b2fe0e4-55a1-4c38-9a68-857313b4690d
More Info
expand_more
Publication Year
2011
Language
English
Research Group
Water Resources

Abstract

Type: Pressure Sensor Keller DCX-4.0, SN 1454
This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: hV=0.145m.
The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff).

No files available

Metadata only record. There are no files for this record.