Retrofitting for Heat Resilience

A Dutch case study integrating overheating mitigation into cost-benefit analysis

Master Thesis (2025)
Author(s)

T. Lalyko (TU Delft - Architecture and the Built Environment)

Contributor(s)

S. Bianchi – Mentor (TU Delft - Structures & Materials)

A. Luna Navarro – Mentor (TU Delft - Building Design & Technology)

Diletta Ricci – Graduation committee member (TU Delft - Design & Construction Management)

Faculty
Architecture and the Built Environment
More Info
expand_more
Publication Year
2025
Language
English
Coordinates
51.911389, 4.442000
Graduation Date
03-07-2025
Awarding Institution
Delft University of Technology
Programme
['Architecture, Urbanism and Building Sciences | Building Technology']
Faculty
Architecture and the Built Environment
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

With climate change increasing the frequency and severity of heat waves in the Netherlands, the risk of buildings overheating poses a critical challenge to occupant health, energy efficiency, and sustainability goals. Despite regulatory progress on reducing energy-related emissions, current renovation practices often overlook overheating issues.
This study addresses this gap by integrating heat hazard loss as cost into a probabilistic cost-benefit analysis to assess the long-term benefits of improving resilience. The method can assist in decision-making when retrofitting by informing about the financial feasibility of mitigation, including the impact of recurring extreme events.
In a case study, renovation alternatives were tested on a housing unit in Rotterdam. The performance was evaluated considering energy efficiency, heat resilience, and carbon footprint. Using the developed framework, the distribution of costs and cost recovery under climate uncertainty were investigated.
The findings show that while passive cooling measures can significantly reduce overheating, their cost recovery is limited under current climate conditions. Still, the financial analysis shows that resilience improvements prevent operational cost from overshooting in the worst-case scenarios. Finally, integrating heating with cooling in a cost-benefit analysis can disclose counteracting measures that reduce the net benefit.
The study demonstrates that further investigation into cost-effective climate adaption is crucial to building future-proof environments.

Files

License info not available
License info not available
License info not available