Multi-scale calibration of a line-style sand pluviator

Journal Article (2024)
Author(s)

Yifan Yang (Student TU Delft, Northwestern University)

D.A. de Lange (Deltares, TU Delft - Geo-engineering)

Huan Wang (Norwegian Geotechnical Institute, TU Delft - Geo-engineering)

A. Askarinejad (Swiss Federal Office of Energy, TU Delft - Geo-engineering)

Geo-engineering
DOI related publication
https://doi.org/10.12989/gae.2024.37.5.431
More Info
expand_more
Publication Year
2024
Language
English
Geo-engineering
Bibliographical Note
Green Open Access added to TU Delft Institutional Repository as part of the Taverne amendment. More information about this copyright law amendment can be found at https://www.openaccess.nl. Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public. @en
Issue number
5
Volume number
37
Pages (from-to)
431-441
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

A newly developed line-style sand pluviator has been calibrated to prepare repeatable sand specimens of specific statuses of compactness and homogeneity for laboratory tests. Sand is falling via a bottom slot of a fixed hopper, and by moving the sample container under the slot, the container is evenly filled with sand. The pluviator is designed with high flexibility: The falling height of sand, the hopper’s opening width and the relative moving speed between the hopper and the sample box can be easily adjusted. By changing these control factors, sand specimens of a wide range of densities can be prepared. A series of specimen preparation was performed using the coarse Merwede River sand. Performance of the pluviator was systematically evaluated by exploring the alteration of achievable density, as well as checking the homogeneity and fabric of the prepared samples by CT scanning. It was found that the density of prepared coarse sand samples has monotonic correlations with none of the three control factors. Furthermore, CT scanning results suggested that the prepared samples exhibited excellent homogeneity in the horizontal direction but periodical alteration of density in the vertical direction. Based on these calibration test results, a preliminary hypothesis is proposed to describe the general working principles of this type of pluviators a priori, illustrating the mechanisms dominating the non-monotonic correlations between control factors and the relative density as well as the vertically prevalent heterogeneity of specimens. Accordingly, practical recommendations are made in a unified framework in order to lessen the load of similar calibration work.

Files

232161754TIB-1.pdf
(pdf | 1.65 Mb)
- Embargo expired in 06-04-2025