Enhanced Optical Sensing Methodology for Wearable Cardiovascular Monitoring: Initial Outcomes

Abstract (2026)
Author(s)

Micha De Bont (University of Twente)

Tom Knop (University of Twente)

Ingemar Fredriksson (Perimed AB, Linkoping University)

Wiendelt Steenbergen (University of Twente)

N. Bhattacharya (TU Delft - Mechanical Engineering)

A. Chizari (TU Delft - Mechanical Engineering)

Research Group
Optical Technologies
More Info
expand_more
Publication Year
2026
Language
English
Research Group
Optical Technologies
Event
First Dutch Biomedical Optics Meeting (2026-06-18 - 2026-06-19), University of Twente, Enschede, Netherlands
Page Views
47

Abstract

Background: Noninvasive optical modalities such as diffuse correlation spectroscopy (DCS) and photoplethysmography (PPG) provide valuable physiological information, particularly for cardiovascular assessment. The emergence of compact, wearable optical devices has expanded their use in point-of-care settings and enabled continuous cardiovascular monitoring in daily life.

Objective: This study introduces a systematic methodology for the informed design of optical transceivers to maximize signal quality. Specifically, we investigated how depth sensitivity depends on tissue scattering characteristics and source-detector distance (SDD).

Methods: Speckle variance optical coherence tomography (svOCT) was performed on six healthy adults (three females and three males) to obtain three-dimensional angiograms of the cutaneous microvascular network. Machine vision algorithms were used to quantify key microvascular characteristics, including vessel depth, diameter, and volumetric density. These measurements were incorporated into a multilayer digital model of human skin, and Monte Carlo simulations of light propagation at 660 nm were conducted over a range of SDDs. By monitoring photon scattering events within individual skin layers, depth sensitivity was quantified as a function of SDD.

Results: The simulations revealed a strong dependence of depth sensitivity on SDD. At a short SDD of 0.15 mm, photon scattering occurred primarily in the upper dermis, accounting for 48.8% of all scattering events. At a larger SDD of 4 mm, the hypodermis became the predominant contributor, representing 40.8% of scattering events. Using the measured mean microvascular depth of 136 ± 43 µm within the upper dermis, an optimal SDD of 0.75 mm was identified, corresponding to a maximum scattering contribution of 56.5% from the target vascular layer.

Conclusion: The proposed methodology provides a framework for patient-specific optimization of optical signal acquisition and can be extended to diverse populations, including older adults and individuals with hypertension.

Significance: By incorporating individual physiological characteristics, such as variations in microvascular structure and skin pigmentation, this approach supports the development of personalized optical sensing devices with improved measurement performance.

No files available

Metadata only record. There are no files for this record.