Axial resistance of CFA piles in Dublin Boulder Clay

Journal Article (2008)
Author(s)

Kenneth Gavin (University College Dublin)

David Cadogan (Cork Institute of Technology)

Lloyd Twomey (Arup Consulting Engineers)

Affiliation
External organisation
DOI related publication
https://doi.org/10.1680/geng.2008.161.4.171
More Info
expand_more
Publication Year
2008
Language
English
Affiliation
External organisation
Issue number
4
Volume number
161
Pages (from-to)
171-180

Abstract

This paper describes the results of static compression and tension load tests performed on three-instrumented large-diameter continuous flight auger piles installed in Dublin Boulder Clay. The piles developed very high shaft resistance and, in contrast to piles driven into Boulder Clay that exhibit friction fatigue, the shaft distribution was uniform along the pile shaft. This resulted in the normalised average shear resistance being mobilised by a bored pile exceeding that of a pile driven in similar ground conditions. In contrast, the base resistance of the test piles was significantly lower than that of a pile driven in similar ground conditions.

No files available