On-line monitoring of ozonation through estimation of Ct value, bromate and AOC formation with UV/Vis spectrometry

Journal Article (2016)
Authors

PS Ross (TU Delft - Sanitary Engineering, ARCADIS Nederland)

A. W C van der Helm (Waternet)

J. van den Broeke (Optiqua Technologies)

Luuk Rietveld (TU Delft - Sanitary Engineering)

Research Group
Sanitary Engineering
Copyright
Campus only
To reference this document use:
https://doi.org/10.1039/c5ay03308j
More Info
expand_more
Publication Year
2016
Language
English
Copyright
Campus only
Research Group
Sanitary Engineering
Issue number
15
Volume number
8
Pages (from-to)
3148-3155
DOI:
https://doi.org/10.1039/c5ay03308j

Abstract

The application of ozone in water treatment serves many purposes, such as disinfection and degradation of organic micro-pollutants. To optimise the applied ozone dosage by on-line control, real-time information on the actual Ct value, the bromate and assimilable organic carbon concentration (AOC) is necessary. With UV/Vis spectroscopy, algorithms have been developed for the on-line determination of the Ct-value and the formation of bromate and AOC during ozonation. It was shown that these algorithms allow for the calculation of the optimal ozone dosage and provide a reliable indication of the amount of bromate and AOC formed during ozonation.

No files available

Metadata only record. There are no files for this record.