On-line monitoring of ozonation through estimation of Ct value, bromate and AOC formation with UV/Vis spectrometry

Journal Article (2016)
Author(s)

P. S. Ross (TU Delft - Civil Engineering & Geosciences, Arcadis)

A. W C Van Der Helm (Waternet)

J. Van Den Broeke (Optiqua Technologies)

L. C. Rietveld (TU Delft - Civil Engineering & Geosciences)

Research Group
Sanitary Engineering
DOI related publication
https://doi.org/10.1039/c5ay03308j Final published version
More Info
expand_more
Publication Year
2016
Language
English
Research Group
Sanitary Engineering
Journal title
Analytical Methods
Issue number
15
Volume number
8
Pages (from-to)
3148-3155
Downloads counter
254
Collections
Institutional Repository

Abstract

The application of ozone in water treatment serves many purposes, such as disinfection and degradation of organic micro-pollutants. To optimise the applied ozone dosage by on-line control, real-time information on the actual Ct value, the bromate and assimilable organic carbon concentration (AOC) is necessary. With UV/Vis spectroscopy, algorithms have been developed for the on-line determination of the Ct-value and the formation of bromate and AOC during ozonation. It was shown that these algorithms allow for the calculation of the optimal ozone dosage and provide a reliable indication of the amount of bromate and AOC formed during ozonation.