Influence of marker-selection method in radiostereometric analysis of total knee arthroplasty on tibial baseplate migration patterns

a secondary analysis of a randomized controlled trial with 5-year follow-up

Journal Article (2024)
Author(s)

T.J.N. van der Lelij (Leiden University Medical Center)

Lennard A. Koster (Leiden University Medical Center)

P.J. Marang-van de Mheen (TU Delft - Safety and Security Science, Leiden University Medical Center)

Sören Toksvig-Larsen (Hässleholm Hospital, Lund University)

R.G.H.H. Nelissen (Leiden University Medical Center)

B.L. Kaptein (Leiden University Medical Center)

Safety and Security Science
DOI related publication
https://doi.org/10.2340/17453674.2024.40184
More Info
expand_more
Publication Year
2024
Language
English
Safety and Security Science
Volume number
95
Pages (from-to)
157-165
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Background and purpose — Different marker-selection methods are applied to represent implant and tibial seg-ments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations (“consistent-marker method”) is used or all available markers at each follow-up (“all-marker method”). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. Methods — Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evalu-ated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. Results — Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval –0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. Conclusion — Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.